Search: toshiba
Results: 5617
Make Model Symptom Problem Solution By
TOSHIBA 2999
LM8
Turns on, when it turns off it no longer works. Changed power supply Replace the c819, 47/50 with a 100/50 soyti
TOSHIBA TV2177 (A) SL
Intermittent power supply, stop This TV came to me with the horizontal output shorted, after changing it it didn't work after checking the power supply I identified that the tl431 was open after changing it the TV started to discharge and cut out, I identified the r851 fir and the TV started working normally again. R 851 220k e la76 431, tl431 FERNANDO
TOSHIBA TV 2916
LEM9
Low power supply with + - 80 v and pulsing 878 resistor altered from 34k to 49k Replace resistor DEBIQUE
TOSHIBA TV2134SL
SK 11
+b voltage changed from 114v to 152v C 634 (47x160)dry generating noise I replaced the c634 and c311 and everything was ok. digitec eletronica by lambarí d'oeste-mt
TOSHIBA 1482BAV
U8
Turns on, turns on stand by but does not oscillate Solution: change tsh q 404 (bu 2506dx) BARRETO CRUZ
TOSHIBA 1482BAV
U8
Horizontal closing right side of the screen Solution: replace capacitor 442 (5n6/3/1k6) BARRETO CRUZ
TOSHIBA 2916
3400
Red with retrace line after working a lot on the board I discovered that the tube was shorted in the red position Tube replacement INOCENCIO
TOSHIBA TV 2134
Extreme width, shrunken vertical and high average 160v power supply See r851 changed correct value 220k Master Eletronica
TOSHIBA 2134
SK11
This one had a stand by light but it didn't oscillate as if it were the flay back. It tried to leave, but it set up protection. After racking my brains I found the c634 completely sold out. Replace c634 chines eletronica
TOSHIBA 2079FMS
Before leaking on the flyb. blue screen, it doesn't work at all. Release or replace d901.on the kinescope plate. JN ELET. NEVES CE
TOSHIBA TV2050 MAV
U17
Dark image C902 on defective kinescope board Jaison
TOSHIBA TV 2095JM
TV turns on normally. then tsound is a blue screen. Release smd transistor on the kinescope q906 board. JN ELET. NEVES CE
TOSHIBA TV 2076BMU
No subtitles, TV works normally. Res. of 100k open near the fly back. JN ELET. NEVES CE
TOSHIBA 2090
U14
Does not turn on dead power supply and str 5753 burst. The str itself is shorted r876 smd of 220 r open d876 of 5v6 shorted and c864 swollen After replacing all the components mentioned, the TV worked perfectly. Let's post more tips guys. This email address is being protected from spambots. You need JavaScript enabled to view it.
TOSHIBA TV2959JFS
LEM10
Burning horizontal outlet and not opening vertical D440 e d408 D440 measures normal but with very high frequency burning at sh and the d408 even measuring well did not rectify the 12v supply to the vertical oscillator..solution to replace both without testing palauro
TOSHIBA 1480
U13
It works with a loud hiss on power supply m, the screen flashes and the str-g5653a heats up abnormally R876 changed its value is 680Ω and it was giving 8k2. Just replace r-876 = 680Ω samuel leite
TOSHIBA TV2091
U14
Stop. not even the LED lights up Capacitor seco e vertical Replace capacitor c887 100mf/16v, replace ci q301 stv9302a lider eletronica
TV-TOSHIBA TV-2916NMS
It turns on normally, but the screen is closed on both sides horizontally and the wid function does not adjust in service mode. The memory and width capacitors were changed, but it didn't solve the problem and the qd01 and qd02 were shorted and the width went back to normal. Adilson(formiga- mg)
TOSHIBA TV2090
U14 U13
Standby Transistor bu808dfi Replace with bu508dfi replace transistor 2sc1815 capacitor 47x35 buster capacitor 8n2 cico
TOSHIBA TV2090I
U14
Vertical function worked normally because at some point it would close and sometimes it would come back and hold After changing everything from the vertical, I had the same problem, after changing the 7805 regulator and 10x35 capacitor, everything was ok. Replace the regulator and 10mf electrolytic capacitor together and then do the reset cico ibimirim pe