Search:
Results: 87722
Make Model Symptom Problem Solution By
SONY CDP101
Distorted sound The unit had a very slight distortion in the sound on bothchannels. between selections or when playing back a single sine wave(yeds-7) noise could be seen occurring at about 13-14 khz.
SONY SL2710
Beta hifi mute in x2 mode Unit worked in all functions except that the beta hifi wouldmute in x2 mode. we found that q14 was turning on in x2 mode despite thefact that af mute line/cn403 was low. there was sufficient forward biasthrough d015 to turn it on. this was remedied by
SONY KV1397
Smeared video The video was smeared and low level. also the freq responsewas low. we found the collector vol at the video drives to be incorrect.this was caused by open choke in the 180v line.
SONY KV5000
No start This unit int. would not start up. c611 was leaky andchanged in value. also, whistle and develop severe pie crust effect.this was caused by c608/pr bd, the cap had changed in value.
SONY KV1311CR
Aux displayed all the time, see service bulletin 208r1 Unit displayed aux every time a channel was displayed. itwas possible to remove the aux with a remote hand unit but it wouldreappear whenever the channel was changed or the unit was turned on.changing the memory ic-105 solved the problem.
SONY CCDV8AFU
S/m correction (x701, crystal osc) Part # given in manual is incorrect. itnector on xf3000. correct # is in ccd-v8 s/m and is 1-567-305-11. -hq comments: this info. will be published shortly as a s/b.
SONY KV25XBR
Loose color after two hrs of operation Loose color in several channels after two hrs of operation.
SONY KV2782R
Swoosh noise at power off, see sb ctv0259 When tuning power switch off a swoosh noise appears at thespeaker.
SONY SPP22
No part number Need part number for board located behind key pad. -hq comments: part number for the pcb is 9-984-490-01. we will issue as/b.
SONY KV25XBR
Color beat interference and herring bone Color beat interference on ch. 27, 28, 29. only on cable,seems to be chassis pick up related, and temperature related. cooling ofic201 fixes problem. -hq comments: try following countermeasures: 1) readjust rf afc, rv201.2) change c203 value to 7pf.
SONY KV2680R
Color beat interference and herring bone, counter measure Color beat interference on ch. 27, 28, 29. only on cable,seems to be chassis pick up related, and temperature related. cooling ofic201 fixes problem. -hq comments: try following countermeasures: 1) readjust rf afc, rv201.2) change c203 value to 7pf.
SONY CDP302II
Not compatible with rm-s410 and remote Cannot plug in 4 pin remote cable from rm-s410. you must useboth remotes.
SONY KV1952RX
P/n not in s/m, m block holder, p/n 4-359-114-01 Part not listed. -hq comments: the part # for the m block holder is 4-359-114-01, butit is not stocked in kc. it can be had on special order from japan.
SONY WMF75
Loose screw on main pcb Whenever this screw becomes the slightes bit loose unit willhum on tape. this can happen in a very short time. -hq comments: in order to prevent the screw from becoming loose, use alockwasher between the screw and the board as shown.
SONY KV25XBR
No video No video, all other functions ok. video present at input ofic301, but no video at output. pin 35, ic301 had 2.7vdc causing blanking,this voltage was caused by shorted evp transistor q1504 and open zenerdiode d1505.
SONY EVS700U
Missing part number (rubber feet) No part number listed for the rubber feet in this model. -hq comments: part number is given on page 150, ref. #107, p/n3-670-155-11. there is currently stock in kc, so you should have nofurther problems.
SONY SL2000
No play or record, shuts down Brake solenoid would energize or turn on. solenoid and q602got hot. base of q602=12, c=5.5v. q602 is a pnp transistor. the cbleakage kept it on. q604 was open.
SONY XR70
Intermittent display Display int. especially when first turned on. radio freq.display would blink in and out with the clock display. fm led would bevery dim then with time become gradually brighter. radio display wouldstabilize and radio come on. found irregular low outp
SONY CDX5
Would not load disc This unit would not load disc. due to operating pressures thee ring wore out the groove in the shaft for the locking e ring. the lock-ing ring groove is completely worn out.
SONY KV25XBR
Muted raster and sound. Ic1501 was shorted and r1552 was open. this was a very dif-ficult problem to troubleshoot because there was no raster at all and thesound was muted. the rgb and sleep leds were also lit. with all thesesymptoms you could be led to the system control ci