Make Model Symptom Problem Solution By
SONY KV2681R
Dead, resolder t-501g Dead. set does not turn on at all. no signal at base ofhoriz. out. q504. however, there is signal at q503 collector.
SONY KV1913
Shut down Customer had unit into fsc four times for regulator failure.found hvr assy cracked. set has been operating for three months withoutfurther failure of regulator.
SONY CCDV8
No drum rotation No drum rotation. signals reaching drum drive ic.
SONY CCDV8
Power on/off ok, all other functions inoperative 1) power on, drum rotates for approx. 10 sec, then eject ledblinks. all buttons inoperable. 2) capstan motor would not rotate, unitwould only thread/unthread. this occurred after repair 1) was performed.
SONY CCDV8
Rewind button inoperative 1) rewind and review inoperative using rew button (p/b ok).after cue (ff button) is released, unit automatically enters review mode.2) p/b picture noisy.
SONY CCDV8
Tape jammed intermittently Motor intermittently won't start unless rotated manually.
SONY CCDV8
Playback jitter and noise Cleaned, no help.
SONY CCDV8
Pins bent on 24 pin connector Pins 23 and 24 were bent. -hq comments: pins 23 and 24 are not used on the multipin connector.the recommended solution if pins 23 and 24 are bent is to cut them off atthe base.
SONY CCDV8
Intermittent no function Osc change frequency.
SONY CCDV8
No eject Frozen motor.
SONY XR66
Non manual autoreverse Unit will auto reverse at the end of the tape but not whenthe front panel buttons are pushed.
SONY CCDV8
Playback picture unstable after 1 - 2 hours After approx. 1 to 2 hours of operation drum and capstanservos would become erratic. picture would jump from side to side andtracking noise would appear. also, capstan would not run at all. inter-mittent capstan (from play or rec mode) would cause shu
SONY SL2500
Rewind problem Close inspection of enclosed upper drum revealed a slightimperfection (marked). replaced again ok.-hq comments: we will evaluate this sample and inform you of our results.
SONY D5
Static after 10 to 30 mins Unit has static after warm-up.
SONY CCDV8
No eject Unit came in with tape jammed inside. i found that the unitwould not unthread, it would play fastforward and rewind.
SONY CCDV8
Shut down after 5 seconds This particular unit was going into shutdown. after 5 secondsof play, the unit performed all function for that 5 seconds. the onlytime the unit worked without shutting down was on still.
SONY BMC550
Noise in audio on quiet scenes Customer complains about background noise from auto focus andmechanism. cs-5 board changed. -hq comments: due to the proximity of the microphone to the focus andzoom motors, acertain amount of noise is unavoidable during quiet scenes.reducing the gain
SONY CDP102
Wrong motor coil wiring Motor coil wiring is wrong for l152-2 on hook up/board layoutpages. this coil is shown connected out of phase. copy of page 40/41 ofcdp-102 manual attached. note corrected copy. -hq comments: confirmed the wiring of l152-2 should be crossed as youfou
SONY SL2700
Cross talk This unit had bad cross talk on both channels. the outputsfrom the band pass filters was not clean. bpf-801/802/901/902 wereall bad.
SONY CDP200
Drawer will not open The drawer would not open because the chucking motor (m802)gear penetration was too tight.