Search: Grundig
Results: 948
Make Model Symptom Problem Solution By
GRUNDIG CUC3600
No pic - dim vert band Check loptr base wfm - if low or twice normal speed check c507 100µ & ic550 tda8140
GRUNDIG CUC3600
Broad white vert bar & secam light on Bu508a loptr overheating. tda8140 chip faulty - driving it at twice freq
GRUNDIG CUC3600
Breathes with brill Tripler/focus unit u/s
GRUNDIG CUC3500
No sound-vision Check d635 ( bat86 ) short
GRUNDIG CUC3500
No sound/vis - +c volts low at 80v instead of 196v D635 bat86 s/c
GRUNDIG CUC3500
Dead ht low at 80v ( 196v ) D635 sc
GRUNDIG CUC3490
No sound R367 o/c & c366 s/c (audio o/p stage supply)
GRUNDIG CUC3490
No sound Tda448c ic sound chip
GRUNDIG CUC3490
No sound Tda4480 sound chip
GRUNDIG CUC3490
No pic - sound ok Check a1 volts present on crt base - if not sus leakagein socket
GRUNDIG CUC3490
Field non lin C411 1000µ 50v supply to fop chip leaky
GRUNDIG CUC3490
Field fault - non lin with top missing Pin 2 field chip only 12v (24v) c411 1000µ 50v supply smoother u/s
GRUNDIG CUC3490
Dead no line drive or ht Tr651 mains tfmr pins 1-15 o/c, pins 15-17 s/c
GRUNDIG CUC3490
Dead - chopper tr s/c, ht fuse o/c Dry joints pin 5 daughter board
GRUNDIG CUC3490
Dead - chopper tr s/c & fuse o/c C667 2µ2 (2 caps) dry joints or low cap
GRUNDIG CUC3490
Dead O/c ht fuse; s/c chopper tr; sus dry joints pin 5 of daughter pcb
GRUNDIG CUC3400
Tripping comes on if adj line frequency down. C653 ( 4.7u f )
GRUNDIG CUC3400
Tripping Set ht pot r637
GRUNDIG CUC3400
Startup - no s/up - ticking from transformer. C653 ( 4.7nf ) connected to pin 15 of ic.
GRUNDIG CUC3400
Poor r/c response R1212 33r missing in sensor pcb