Search: Grundig
Results: 948
Make Model Symptom Problem Solution By
GRUNDIG CUC3400
Poor purity & focus. C433 ( 1 , 000uf , 25v )
GRUNDIG CUC3400
No start up with ticking Ht at chopper coll - c653 4n7 connected to pin 15 power chip u/s
GRUNDIG CUC3400
No start up - ticks C653 4n7 connected to pin 15 of power chip u/s
GRUNDIG CUC3400
No sound C266 1000µ 25v s/c; r367 8r2 safety res o/c
GRUNDIG CUC3400
No chan change when cold - display changes ok tho' Dry joint pin 15 tuner/if socket
GRUNDIG CUC3400
Int or perm tripping - ok on dummy load Timing cap c653 4n7
GRUNDIG CUC3400
Int dead Pin 0 on lopt (eht overwind) arcing internally - new lopt reqd
GRUNDIG CUC3400
Int colour & rh side of pic blanked Tda2579 timebase chip
GRUNDIG CUC3400
Dead. Drys on main pcb.
GRUNDIG CUC3400
Dead, 800ma si642 fuse o/c, chopper t661 but11a s/c Check for dry joints ipsalo tfmr or d663, 664 & 666 faulty also check c667 2µ2
GRUNDIG CUC3400
Dead with buzz from ipsalo tfmr The +m supply ok at 11v in st/by but dropped instead of increasing to 20v when sw on. c630 0µ68 leaky
GRUNDIG CUC3400
Dead or tripping Set ht pot r637, d666 byv16 s/c, d664 ba159 s/c or ic686 78m05 s/c
GRUNDIG CUC3400
Dead 800ma fuse blown Dry joints on chopper tx check d663 664 666 c653 4n7 c667 2u2
GRUNDIG CUC3400
Dead - repeatedly blows t661 Replace ic655 tda3640, d666 rgp30m, r637 1k preset, c661 47µ 63v, d662 zpd3v9, r661 1r & c667 0µ15 or 2µ2
GRUNDIG CUC3400
Dead - all fuses intact D691 byv28/100 s/c (20v supply)
GRUNDIG CUC3400
Dead - & tripping. Set ht control ( r637 ) int o/c , d666/d664 s/c , ic686 78m05
GRUNDIG CUC3400
Dead On/off sw u/s chs - g102
GRUNDIG CUC3400
Blue raster with fb lines Tda3505 vid proc chip ic9531 on chroma board
GRUNDIG CUC3400
Arcing/random chan change Triple
GRUNDIG CUC3400
+b decreasing when average brightness of picture increases. Change c611 47uf cap.