GRUNDIG CUC2201
Int trips at sw on R637 1k set ht pot
GRUNDIG CUC2200
Small pulsating raster. Di614 ( 75v zenor ) in cutout circuit rev leak around 100k
GRUNDIG CUC220
Startup - switch on problems & hum. Relay contacts jammed o/c.
GRUNDIG CUC220
Standby- intermittent going into standby. Ic663 ( 5v reg )
GRUNDIG CUC220
Standby - intermittent going into standby. Change r647 to ceramic.
GRUNDIG CUC220
Shutdown - intermittent switching off. Dry r646 ( 270k ) , tda4600 , replace ht pot r647 ( 2.5k )
GRUNDIG CUC220
Pulling/rolling C2216/2221 1µ 63v in if can by tda5500 chip
GRUNDIG CUC220
No vision with raster and sound. T2533 , adj control sb , r2536 , c2536 , d2536 , d2532
GRUNDIG CUC220
No pic at switch on - looks like its off tune C2221 ( 1uf 63v ) in tuner/if unit.
GRUNDIG CUC220
Lack of frame at bottom when cold. C2768 ( 100uf ) on deflection pcb.
GRUNDIG CUC220
Interference at sides. Ic tda2595 sync/line osc ic.
GRUNDIG CUC220
Int start up Tda4600
GRUNDIG CUC220
Int start up C631 100uf 40v , c633 220uf , c647 1uf , c642 100uf + r646 270k
GRUNDIG CUC220
Horizontal shaking. Tuner/if dry joints , check the electrolytics with freezer
GRUNDIG CUC220
Goes straight off at sw on Odd characters in display - ht = 180v (109v) ht pot int
GRUNDIG CUC220
Frame distortion. Ic tda1770 if used , d2761 ( ske4g1/04 ) , r2761 ( 6.8Ω , .75w )
GRUNDIG CUC220
Frame collapse. R2779 ( 18k ) o/c remove to check.
GRUNDIG CUC220
Excess col & brightness when heated Ok when txt pcb dis'd - left it this way
GRUNDIG CUC220
Display - intermittent incorrect channel disp Ic663 ( 5v reg )
GRUNDIG CUC220
Dead - intermittent. R646 ( 270k ) on psu.