HITACHI |
G6P
|
Light horizontal bar at top of pic | Cp901 chopper drive chip | ||
HITACHI |
G6P
|
Int sticks in stby | R1172 dry between pin 38 micro and q1103 | ||
HITACHI |
G6P
|
Int start up | C911 2µ2 50v non pol cap in psu | ||
HITACHI |
G6P
|
Int dead no ht | Eht sensing diode zd752 slight reverse leak - 24v zener | ||
HITACHI |
G6P
|
Int cuts out after trying to start | 2d752 24v zener | ||
HITACHI |
G6P
|
Green flashing pic with green fingers reaching out from left | Caption/on screen display gen chip ic1104 m50450-023p | ||
HITACHI |
G6P
|
Green flashes on picture | Replace osd id | ||
HITACHI |
G6P
|
Going to standby at switch on. | R902/3 ( 82k ) high. | ||
HITACHI |
G6P
|
Goes straight to stby | R902 903 82k high or oc | ||
HITACHI |
G6P
|
Field top foldover | C682 100µ 50v | ||
HITACHI |
G6P
|
Field cramp | C682 100µ 50v | ||
HITACHI |
G6P
|
Fail to start up - int | Dry joint r1172 1k between pin 38 of micro & q1103 coll | ||
HITACHI |
G6P
|
Excess brill with fb lines | Zd301 12v leaky across lum feed to crt panel | ||
HITACHI |
G6P
|
Dead, st/by led ok, ht at 40v on dummy load | C914 1000µ 16v | ||
HITACHI |
G6P
|
Dead without whistle | D902 es1a s/c in psu | ||
HITACHI |
G6P
|
Dead with whine | Ht low at 50v on dummy load - loptx s/c winding | ||
HITACHI |
G6P
|
Dead line tr reads sc or low b-e ( q901 ) | Cp901 hm9205 sc pins 5 , 6 | ||
HITACHI |
G6P
|
Dead after dying whine at sw on | Dry joints line driver tfmr t721 lands | ||
HITACHI |
G6P
|
Dead - momentary crack from spkr & led briefly flashes | Ok on dummy load - loptx faulty | ||
HITACHI |
G6P
|
Dead - low res between base - emitt of chopper transistor q901 | Cp901 control/drive module hm9205 has s/c between pins 5 & 6 |