Search: hitachi
Results: 1065
Make Model Symptom Problem Solution By
HITACHI CPT2488 SAL K
Blanked out pic except for top and bottom of scr C574 100mfd , 40v
HITACHI CPT2488
Blanked out pic apart from strip at top & bottom - improves with heat C574 100µ 40v in field timebase
HITACHI CPT2476
Int power off Focus spark gap dirty & int arcing
HITACHI CPT2476
Bright pic varying left to right Cap in 200v supply on crt base
HITACHI CPT2288DS
Standby - led on - dead. Ll04 o/c - may be able to unwind & refit.
HITACHI CPT2288DS
St/by only No o/p from sw mode psu as ll04 coil o/c
HITACHI CPT2282
Dead aft degaussing therm blown Replace mains fuse & thermistor (p181 from chs works) - won't work without this dual role therm
HITACHI CPT2250 J
No startup. I will go 12.
HITACHI CPT2218
Field cramping Replace c608 22mfd250v
HITACHI CPT2218
Field cramp C608 22µ 250v
HITACHI CPT2198
Blank white raster C720 in rgb 200v supply
HITACHI CPT2188 IPSALO
Line tearing + int blue screen Pin 13 icb500 should be 11v if not replace tda 2579
HITACHI CPT2188 IPSALO
Int won't start C604 1000uf 25v
HITACHI CPT2188
No display or tuning Cc107 220µ 16v by saa1294 control chip
HITACHI CPT2188
Int failure to start C604 1000µ o/c
HITACHI CPT2176
Field - top foldover C682 1000µ 50v in fop stage hi esr
HITACHI CPT2158 NP85CQMK2
Poor pic - dark & streaky Zd801 3v3 zener on crt base leaky
HITACHI CPT2158
Blank raster & max sound No 5v to micro - d911 dry joint
HITACHI CPT2138
Blank grey raster, no sound for first few mins C922 470µ 25v hi esr
HITACHI CPT210
Bright raster esp on rh side with smearing 200v supply to crt pcb low due to c719 4µ7 250v o/c