Search: hitachi
Results: 1065
Make Model Symptom Problem Solution By
HITACHI G6P
Dead Q901 or dry joints on heatsink tag for t721
HITACHI G6P
Dark pic with red flaring Low a1 volts caused by contamination on crt base pcb
HITACHI G6P
Corrugated verts C905 & c910 4µ7 50v
HITACHI G6P
Colour int goes off Ic501 ha51338sr pin never soldered
HITACHI G6P
Colour - looks a bit pale. Q856 ( 2sc2271 )
HITACHI G6P
Bright white raster which trips after 30 seconds R771 o/c & d763 leaky in rgb supply
HITACHI G6P
Bright white raster - only 20v at rgb colls Zd301 12v zener on main pcb
HITACHI G6P
Bright green raster with flyback lines. when the A new cbip restored everything to normal.
HITACHI G6P
Blank white raster with fb lines Q301 2sa673c s/c,replacement restored pic but no osd & red fb lines; m50450-023p micro
HITACHI G6P
Blank raster, no sound Ic932 12v reg o/p low, c933 2200µ 25v
HITACHI G6P
Blank raster , no sound C933 2200mfd , 25v also check 12v reg op. ic932
HITACHI G10Q C2564 ETC
Repeated failure of e/w diode d704 by228 which causes tripping & blowing fuse f902 Also replace q651 bu801 pt no t636046 & q652 bc548b, l651 filter coil pt no 2220642 (goes shorted turns)
HITACHI G10Q C2564
Int start up C927 470µ 25v in 12v line
HITACHI G10Q
Trips until heated Zd945 bzv10 - normally reads o/c both ways
HITACHI G10Q
Trips until heated C927 470µ & dry joints 12v reg ic921
HITACHI G10Q
Tripping Check audio pcb by disconnecting it
HITACHI G10Q
Tripping Check f902 630ma fuse on lop panel & dry joints & ic80 heatsink on crt base
HITACHI G10Q
To enter service mode Press vol + & - together whilst sw on from mains. press the 2 vcr rec buttons on hset together twice - 'tube' now displayed
HITACHI G10Q
St/by led pulsing Opto1 cnx82 part no t548009
HITACHI G10Q
Poor start or st/by only Dry joints ic952 (under plastic rail)