PHILCO CPH 04
Inoperative, the power supply does not arm Capacitor c 716 (6 n 8 x 1600 v) shorted
PHILCO CPH 04
Horizontal frequency varying, image with colors tending to green and violet Crystal x503 (3.58 mhz) broken
PHILCO CPH 04
Turns off after running for a few minutes Resistor r 713 ( 4.7 k si) open
PHILCO CPH 03
Lack of horizontal synchronism Capacitorc 613 (18 pf) with leak
PHILCO CPH 03
When turned on, the power power supply burns out (str series) Diode d 909 or capacitors-c 910 or c 925 shorted (both 4.7ufx160v)
PHILCO CPH 02
Vertical with insufficient height, rounded dark band at the top Resistor r612 (12k x 500 v) with changed resistance or open
PHILCO CPH 02
Intermittently reduced vertical scan Resistor r 616 ( 3,3 k q.) aberta
PHILCO CPH 02
Dark screen, normal audio Resistor r 761 f 39 k ) open
PHILCO CPH 02
Distorted sound Resistor r418 (100 ) 0.75 w aberto
PHILCO CPH 02
Without mat, voltage on the base of q 704 at 17...18 v, filament voltage of the trc at 2v. broken tsh symptom Capacitor c 709 (4 n 7 x 50 v) shorted
PHILCO CPH 02
No chroma, normal audio Capacitor c 515 (47 k - disc) leaking or shorted
PHILCO CPH 02
No chroma PAL delay line (dl 501) with broken internal contacts
PHILCO CPH 02
No audio, no video Capacitor c 911 (10 u fx160- v) with loss of capacitance or high esr
PHILCO CPH 02
Off-frequency vertical sweep oscillator: "rolling" image Capacitor c 604 (1 u f x 25v) with loss of capacitance or high esr
PHILCO CPH 02
Does not memorize channels Capacitor c715(4u7x160v) with loss of capacitance or high esr
PHILCO CPH 02
Raised mat, high-voltage exhaust on trc socket Resistor r911 (10k open
PHILCO CPH 02
Dark horizontal line dividing the dotrc screen Capacitor c 614 (4.7u f x 50 v) with loss of capacitance or high esr
PHILCO CPH 02
Dead, no plot, no audio Diode d 906 (ske 4f2/06) with leakage and/or resistor r 909 (82 k q) open
PHILCO CPH 02
Inoperative, protection circuit acting Capacitor c 719 (1 u f x 63v) with loss of capacitance or high esr
PHILCO CPH 02
Dead, no audio Capacitor c 912 (220 u. f x 160v) with cold solder on the terminals