Make Model Symptom Problem Solution By
PHILCO PCR1449
Works and then turns off Zd941 (30v)
PHILCO CPH-05
Contrast control inoperative R717(82k or 100k) with changed or open value
PHILCO CPH-05
Turns off for no apparent reason. R706(10k)
PHILCO CPH-05
No color C212(100nf)
PHILCO CPH-05
Poor vertical deflection 680k r601 changed
PHILCO PCS 2700
Saturated image with return line R715 de 4,7Ω o c718 de 470pf e o d701
PHILCO PCS 2700
Image shaking vertically C 723 of 2.2x 63 v
PHILCO PC2025
No image and sound. when it turns on it makes a noise and stops. Q903 bf42
PHILCO PC2004
Horizontal dark bar C607 10uf-160v
PHILCO PC2004
Without vertical and horizontal synchronization C701 820pf
PHILCO PCM 1444
Turning off C 706
PHILCO PCR- 2049
Audio chiando C401 820pf
PHILCO PCR-1447
Dead C710 (33nf) e ou fly back
PHILCO PC2004
No image and sound C916 390pf-500v
PHILCO PVM2050
No image and no sound R712 4k7-3w open
PHILCO PCM 1444-2044-2144
Vertical closed R601 (680k)
PHILCO PCM 1444-2044-2144
Image coming and going (circ/ prot/ actuando) R713- 100k
PHILCO PC2043
Violet color screen C515 22n
PHILCO CPH 05
It turns on, but there is no sound or image, there is just a strange noise in the flyback. Ic501 tda8361
PHILCO PCR 1449
After two minutes of normal switching on, the screen darkens C630 de 47k(ceramic)