Search: philips
Results: 14231
Make Model Symptom Problem Solution By
PHILIPS FWM37BK
Does not turn on, display is off Evaluate crystal on 8mhz display board ROBERTO
PHILIPS 20CT6065
No sound and image Ci-tda2577
PHILIPS 29PT752A
Crackling sound Eeprom, fix obs
PHILIPS 29PT752A
Only with drizzle on the main screen, normal on pip and av Q127
PHILIPS 29PT752A
Out of tune Bc547 position 7659
PHILIPS 29PT522A /78R
Blown fuse stop C471, 1k
PHILIPS 16GL1331
Lines at the top of the screen C410-100mf/25v changed
PHILIPS CN4065
No color Ci 200
PHILIPS CN4037
Retrace at the top of the screen Change c400
PHILIPS CN4065
Retrace at the top of the screen Change c400
PHILIPS CHASSIS ANUBIS
ANUBIS
Code defects Number of LED blinks: 1- RAM problems; 2- problem on the das and scl bus; 3- high current in the trc beam; horizontal scan protection.4- vertical scan protection.5- audio processor does not respond to the microcontroller;6- bimos initialization error. 7- general error on bus i 2 c. 8- general error i 2 c.9- eeprom configuration error
PHILIPS NCF
NCF
Code defects F1 - remote control - check the receiver module; f2 - high power supply; f3 - horizontal circuit and power supply; f4 - memory
PHILIPS 29GX1895
ANUBIS_S
Generates mat, has no sound or image Verificar c2451, c2415 e ci do vertical - tda 3654-3
PHILIPS 20PT132 A/78
Return lines (retrace) C2331 (check r3416)
PHILIPS 14GL1319
Vertical closed Check r3229 (1 mega) has a value above normal
PHILIPS 20PT3331
Intermittent sound Verify none 2444
PHILIPS 14PT314 A/78
Retrace lines and acting protection R3334 18k na placa do tubo Elisson Aragão
PHILIPS PT110-112
No horizontal synchronization Capacitor electrolitico c2422
PHILIPS 20GL1045
Weak image, unstable tuning Q195
PHILIPS L01.1L
After a few minutes it turns off Check transistors 7461, 7463 and cap. 4255