Make Model Symptom Problem Solution By
PHILIPS FL1.10 28CL6770
Dead - loptr s/c Check for dry joints at scan coil plug
PHILIPS FL1.10 28CL677/257
St/by only Loptr bu508af s/c due to dry joints scan coil plug
PHILIPS FL1.10
Wrong synchronization, unstable colors D6417 on the lsp dependent on temperature, check/replace (4822 130 81223)
PHILIPS FL1.10
Wrong service batch of st24c08cb1 memory ic's Wrong service batch of st24c08cb1 memory ic's 4822 209 32283 ------------------------------------------------------------ temporarily a wrong batch of earom's has been delivered, causing the fault "nvm memory not write protected" after replacing the earom
PHILIPS FL1.10
Various faults can be observed. Check the earth connection from the ssp: connect earth tuner with earth line output transformer (lsp) to find-out whether the problem is solved. check connectors l02 and s02 pins 1,2 (sometimes only 7 wires are used in the connector)
PHILIPS FL1.10
Unstable picture, horizontal jitter. Check/replace r3405 on the lsp. (4822 051 10303 for 50 hz sets; 4822 051 10333 for 100 hz sets).
PHILIPS FL1.10
Tuning does not function Resistor r3240 on lsp in v-tuning wire broken.
PHILIPS FL1.10
Totally inoperative. only red led on. Check line driver transformer l5503 on lsp (4822 142 40328).
PHILIPS FL1.10
Totally inoperative. Transistors 7250 (bux85f; 4822 130 62509) and 7251 (bc848; 4822 130 61207) in microsops defective. or d6251 (llz-c5v6; 4822 130 80954) and r1250 (=r3230; 1Ω; 4822 052 10108) defective. or t7270 (bd825; 4822 130 41746) or t7201 (bc857c; 5322 130 427
PHILIPS FL1.10
Total inoperative, leds blinking, error 99 Check and replace if necessary c2504 and/or 2505 (2kv hrr) on the large signal panel. replace by a 3kv15 hr-r capacitor if possible: 820pf 4822 126 13152 1nf 4822 126 13153 1,2nf 4822 126 13154 1,5nf 4822 126 13155 1,8nf 4822 126 13156 2,
PHILIPS FL1.10
Synchronization, picture disappears D6703 and t7704 defective on picture tube panel.
PHILIPS FL1.10
Supply switch-off sometimes Check the +5 stand-by. this voltage has to be 5.5v and may not vary. when the voltage drops below 5.2v the set switches-off. cure: check d6266 for leackage (bzx79/f6v8; 4822 130 34278) or check t7268 for leackage (bd943f; 4822 130 62742). the 5.5v is meas
PHILIPS FL1.10
Supply +5v too low, black horizontal bar in picture. bad sync. Check/replace ic7551 (lm358n; 4822 209 70672)
PHILIPS FL1.10
Stripes in picture and after about 5 min. only snow. Replace tuner fq916bl (4822 210 10565).
PHILIPS FL1.10
Spook in picture Use special antenna cables. codenumbers: 4822 321 61224 pal 1 meter 4822 321 61225 pal 2 meter 4822 321 61226 secam 1 meter 4822 321 61227 secam 2 meter
PHILIPS FL1.10
Splitted characters with txt (bad starting of dvtb). Add r3100 (1m 5% 0,5 w; 4822 116 52235), between pin 7 and pin 15 of ic7111 (saa9042) on the lfr box. change 4108 into 220nf 50v (4822 122 32927) on the lfr box. remarks : introduced in production in week 9333.
PHILIPS FL1.10
Sometimes vibration in vertical direction. Replace c2410 (150nf 5%; 4822 121 41854) on lsp.
PHILIPS FL1.10
Sometimes set switched back to standby. only red led on. Microprocessor panel defective (4822 212 30803 and 4822 900 10423)
PHILIPS FL1.10
Sometimes in protection, or hor. width varies Check or resolder on lsp the pins of e/w bridge coil 5521.
PHILIPS FL1.10
Set inoperative only red or green led. supply was 141v but no eht. Line drive puls for t7506 (2sc4288a) too low. l5503 defective (line drive coil; 4822 157 63252)