PHILIPS FL1.0S
Modification improved bandpass for high frequency Modification improved bandpass for high frequency in -/61 sets -------------------------------------------------------------- on the korean stereo panel the following items are changed: - item c2080 added 10nf 50v (4822 121 41857) - item c2083 changed int
PHILIPS FL1.0S
Low frequency hum from subwoofer, buzz from right hand squeeter. Check dc level on pin 1 and 9 of ic7011 (tda1521). if not correct, replace (4822 209 63913).
PHILIPS FL1.0S
Low brightness txt and osd, picture ok If this condition occurs, check the option codes. resetting the option code numbers as per the service manual provided the cure.
PHILIPS FL1.0S
Leds blinking; error code 99. Check ts7504 on the lsp (bu508af; 4822 130 61265). if ts7504 needs to be replaced it is recommended to change r3418 on the lsp into 200Ω (4822 051 10201). remarks : introduced in production in week 9202.
PHILIPS FL1.0S
Jitter In pip unit change the value of r3336 to 4k7.
PHILIPS FL1.0S
Intermittent nicam decoding. Replace c2108 on the multi sound panel into 33pf (4822 126 10324). remarks : introduced in production week 9129
PHILIPS FL1.0S
Intermittent nicam decoding. Replace c2108 on the multi sound panel into 33pf (4822 126 10324). remarks : introduced in production week 9129
PHILIPS FL1.0S
Instant colour/tint change problem. Use latest software version; fl1.0s v1.9 (4822 900 10297) fl1.0s lat/ntsc v2.4 (4822 900 10298) remarks : introduced in production in week 9218.
PHILIPS FL1.0S
During production an eeprom protection panel (4822 During production an eeprom protection panel (4822 212 31266) is introduced. together with this also the following components have to be changed: on the small signal panel: - add position 3256 and 3257 4k7 (4822 051 10472) - delete position 3280 and 3281
PHILIPS FL1.0S
Does not start. Check d6228 on the lsp. if d6628 is defective it should be replaced by s0824nh-1da (4822 130 20277). it is recommended, for pwb version lower than .3, to add a capacitor of 47nf (4822 121 43526) across the cathode and gate of d6228. it is recommended, fo
PHILIPS FL1.0S
Does not start. Check/replace c2241 330 uf (4822 124 42208) on lsp. if c2241 is defective it is recommended to change the value of c2228 on the lsp into 33nf (4822 122 31981). remarks : introduced in production in week 9325.
PHILIPS FL1.0S
Crackling/toggling sound or intermittent nicam sound. This complaint is due to poor reception or reflection problem and is very much depending on the customers location. service solution: - change item 1045 on the multi sound bi nicam panel into adjusting coil 5,85 mhz (4822 156 11157) - change item 1045
PHILIPS FL1.0S
Correction to service information fl 95.01 Correction to service information fl 95.01 ------------------------------------------ correction in the overview of 100hz and proscan boxen. the replacement for service code 4822 212 30534 must be 4822 212 31231 the replacement for service code 4822 21
PHILIPS FL1.0S
Colored picture or picture is green/red, fly-back lines Check zenerdiode 6450 on pin 19-ic7430 on the lsp. new diode must be philips (telefunken does not work), 4822 130 81512
PHILIPS FL1.0S
Channel 21 and 28 frequency range cannot be tuned in. Use software version v2.4 or higher; ic7115 on the ssp (4822 900 10298). remarks : introduced in production in week 9218.
PHILIPS FL1.0S
Bux85f in mikrosops defective Change the value of c2260 to 4n7f, replace 7270 with transistor bd825 (4822 130 41746).
PHILIPS FL1.0S
Bad or no functioning of the tda4680/v4. Check/replace ic7430 tda4680/v4 (4822 209 31592). it is recommended to add a zener diode bzx79-c12 (4822 130 34197) between pin 28 of the tda4680/v4 and anode to ground. remarks : introduced in production in week 9140.
PHILIPS FL1.0S
Bad focus or focus varies in a new set or after crt replacement Possible solution: short circuit the focus and the g2 pins of the picture tube with the aquadag coating. switch the set on for approximately 5 seconds. after this return the set to its original condition. check if the focus adjusted normally. if not repla
PHILIPS FL1.0S
50hz buzz noticable through speaker Check/replace ic7680 on the ssp - tda8425, pseudo stereo ic. (4822 209 63734).
PHILIPS FL1.0AA
Protection mode operated T7542 in prot cct leaky