Search: philips
Results: 14245
Make Model Symptom Problem Solution By
PHILIPS FL1.0
Production modification tda4680 supply Production modification tda4680 supply -------------------------------------- jumper 9481 is replaced with a diode type bat85 4822 130 31983 cathode to pin 5 of ic7430, tda4680 on the ssp. remarks : introduced production in week 9228.
PHILIPS FL1.0
Problems due to cnx83x Change into cny17-3.6 (4822 130 83177) remarks : production intro date: 92-06-18
PHILIPS FL1.0
Pip picture not in order. Check r3345 (4822 111 41424) in pip unit, check ic7755 (4822 209 63423).
PHILIPS FL1.0
Picture twists from top Voltage of pin 8-ic7450 (tda3654q) on the lsp has raised to ca. 20 v. check diode 6451 (bzx79/c3v6; 5322 130 34834 or bzx79/c10; 4822 130 61219)
PHILIPS FL1.0
Picture twists from top Voltage of pin 8-ic7450 (tda3654q) on the lsp has raised to ca. 20 v. check diode 6451 (bzx79/c5v6; 4822 130 80954).
PHILIPS FL1.0
Picture twists from top Voltage of pin 8-ic7450 (tda3654q) on the lsp has raised to ca. 20 v. check diode 6451 (bzx79/c3v6; 5322 130 34834 or bzx79/c10; 4822 130 61219)
PHILIPS FL1.0
Picture moved to the right Voltage of pin 12-ic7400 on the lsp has raised to 1 v (0,6v). check resistor r3408 (33k; 4822 051 10333).
PHILIPS FL1.0
Picture disappears (fly back lines), on stereo and dual leds blink Check ic7430 (tda4680). when tda4680 is too hot there is no picture (4822 209 31592).
PHILIPS FL1.0
Picture disappears Check voltage on tp55 on the lsp. if not correct, check c2528 (4822 121 40336)
PHILIPS FL1.0
Overview of sops repair kits Overview of sops repair kits ---------------------------- fl1.0 ag00 upto ag03 4822 310 20492 fl1.0 ag04 and higher 4822 310 31921 fl1.1 25" and 28" 4822 310 31919 fl1.1 33" 4822 310 31932 fl1.2 4822 310 31932 fl1.6
PHILIPS FL1.0
No stand-by mode In stand-by mode (+141v) is >> 0v. check d6352 and d6353 (ll4148; 4822 130 80446) on the lsp. note: on print lay-out (service printing), the anode and cathode in fl1.0 aa service manual are interchanged. the cathode has to be connected with pin 5 of the s
PHILIPS FL1.0
No sound, "on, standby, i" leds blinking 10mhz crystal 1602 on the ssp defective, 4822 242 80276
PHILIPS FL1.0
No red measure line when set is cold, after 2 minutes set is ok. Ic tda4680 on ssp defective (4822 209 31592)
PHILIPS FL1.0
No picture, sound ok. If burst-key signal is o.k.: check d6404 (ll4148; 4822 130 80446) on the ssp.
PHILIPS FL1.0
No picture, sound is ok. error 00 99 07 15 09. Check r3480 and r3481 on the ssp. (2,7Ω safety resistor; 4822 052 10278).
PHILIPS FL1.0
No picture, only txt/menu/osd and sound. If voltage p13 tda4680 (ic7430) not 0v, t7182 is leaking. replace t7182 (bsr12; 5322 130 44743).
PHILIPS FL1.0
No picture, no sound. error 10. Check ic7115.
PHILIPS FL1.0
No mono sound, nicam sound ok. On checking around ic7200 it was found that there was no 10 mhz clock on pin 4. replacing crystal 1602 (10mhz; 4822 242 80276) cured the fault.
PHILIPS FL1.0
No leds blinking, no +vstart (17,5v), no +5standby (5.5v) Check ts7250 (4822 130 62509; bux85f). in case of a failure of ts7250 it is recommended to change the following components on the large signal panel. position component new code no. c2260 470pf 4.7nf 4822 122 317
PHILIPS FL1.0
No colors in tv mode Check ic7365 (tda4650) on the ssp (4822 209 30837)