Philips Repair Tips
Search: philips
Results: 14245
Results: 14245
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
PHILIPS |
E2
|
Width - reduced & ripple. | R306 ( 22k ) high. | ||
PHILIPS |
E2
|
Sound - distorted. | R306 ( 22k ) high. | ||
PHILIPS |
D16-III
|
Slight patterning useing scart socket. | Mod see tv mag. | ||
PHILIPS |
D16-III
|
Pic flashing - int blanking | Fault on digital board - replacement nec | ||
PHILIPS |
D16-111 33DC2080/25R
|
Dead with r3498 1k5 1/2w overheating | Loptx faulty & replace resistor | ||
PHILIPS |
D16
|
Osd comes on int + int blank screen | Focus arcing in tube base | ||
PHILIPS |
D16
|
No col from cold - ok when warm | Xtal x1207 on dig vid pcb proved to be faulty when sprayed with freezer | ||
PHILIPS |
D16
|
No col & poor sync at sw on - improves with time | Check electrolytics in if module | ||
PHILIPS |
D16
|
Int appearance of osd on its own & int pic off | Focus spark gap arcing - replace crt base | ||
PHILIPS |
D16
|
Dead apart from power on, txt & rgb lights flashing | In prot mode - confirm by scope check of coll tr7657 sm tr - 0v indicates in prot mode - normal when working = 5v; to check which area of set is causing fault monitor the following :- audio - coll tr7130; ew - cct anode d6502; lop - coll tr7495; fop - emitter tr7425. in a correctly working tv all these volts should be zero. in this case there was a high pulse at tr7425 indicating a field fault; no field drive as l5251 was o/c removing supply to dpu2553 dig proc chip | ||
PHILIPS |
CX1120
|
Sound varying. | Djs on earth tags 10 , 16 , 18 , l622 or tuner earthing. | ||
PHILIPS |
CX1120
|
Display - int. | Djs on earth tags 10 , 16 , 18 , l622 or tuner earthing. | ||
PHILIPS |
CX1120
|
Dead | Insufficient line drive to turn on loptr - t534 bc637 low gain | ||
PHILIPS |
CTX-S
|
Black lines across col pic - ok in b/w | C2218 2µ2 63v | ||
PHILIPS |
CTX-E
|
Won't stop in search tune mode | Pin 1 lm339n ic7830 not going low when search button pressed - chip faulty | ||
PHILIPS |
CTX
|
Wrong cols - red = purple, blue = red, grey scale ok | Was degauss therm dry jointed | ||
PHILIPS |
CTX
|
Tripping. | D6590 ( byv95a ) s/c. | ||
PHILIPS |
CTX
|
Tripping | D6583 sc | ||
PHILIPS |
CTX
|
Startup - no start up - intermittent on/off | R3325 set ht pot dirty. | ||
PHILIPS |
CTX
|
Sound - buzzing alters with picture content. | Radiation - via unscreened audio lead. |