Search: philips
Results: 14245
Make Model Symptom Problem Solution By
PHILIPS CTX
Line tearing at top - worse on vcr. C2378 ( 1uf ) dried up.
PHILIPS CTX
Line instability on vcr playback Adjust agc preset r3144
PHILIPS CTX
Int no startup - stations will not store. Battery.
PHILIPS CTX
Int dead Dry joints loptx
PHILIPS CTX
Int colour 0
PHILIPS CTX
Frame collapse - intermittent. Check connections around loptx
PHILIPS CTX
Frame - picture jitter. Drys around loptx
PHILIPS CTX
Field scan noisy Q541(2sd1266) ripple filter tr s/c. (used but11af in lieu)
PHILIPS CTX
Eht & crt heaters ok but no raster & loud hum from R3585 ( 2r2 ) o/c
PHILIPS CTX
Dead. Check r3394/3395 27k , 2.5w for o/c.
PHILIPS CTX
Dead with whistle - ok on dummy load Dry joints c2609
PHILIPS CTX
Dead set screams and blows line op transistor if l C2351 chopper transistor base coupler 4u7
PHILIPS CTX
Dead - overload on lip Eht lead s/c
PHILIPS CTX
Dead - no 125v, faint whine from psu D6317 1n4148 leaky
PHILIPS CTX
Dead - ht low at 50v Trs 7322 & 7323 bc548 and bc558 faulty - (read ok)
PHILIPS CTX
Dead - buzzing from psu & spkr Ht ok - ic7375 tda2577 u/s
PHILIPS CTX
Dead R3298 4r7 dropper o/c
PHILIPS CTX
Dead Crack in print at corner of remote psu
PHILIPS CTX
Dead R3394 r3395 oc 27k 2.5w
PHILIPS CTO/CTX
To reset settings With set sw'd on s/c the left hand side of r3017 to the bottom of r3014