PHILIPS CP90
Int height Dry joints in fop stage & psu
PHILIPS CP90
Int flashing - low gain - poor sync. Drys in if/sync can.
PHILIPS CP90
Int fail to switch on C2700 4µ7
PHILIPS CP90
Int dead with whistle from chopper C2700 4.7uf o/c in the psu.
PHILIPS CP90
Impurity & lines at sw on Degaussing therm 98017 - used 96009 & dry joints loptx
PHILIPS CP90
Function knobs on ctv fail Voltage + 4,9 v on pin 42 ic 7840 present. oscillogramm on pin 31,32 present. replace ic 7840 (tmp47c432p-8188; 4822 310 31849). important: mount the metal-shielding with earth to bridge 9732 (tmp47c432p-8189; 4822 310 31851)
PHILIPS CP90
From cold will come on if warm will not start up D6670 ( in4418 )
PHILIPS CP90
Frame collapse - with small scan below it. Crack in print by r3275.
PHILIPS CP90
Focus fluctuates Tr5763
PHILIPS CP90
Fluttering pic - ht normal C2638 470µ 16v in 13.5v supply or check elect caps in if can
PHILIPS CP90
Flasing/lines on pic when cold Dry joints if module - esp the chips
PHILIPS CP90
Field scan very low ( 1/2 inch ) Raakhdhi A. A. Ahm
PHILIPS CP90
Field collapse with bright line across screen R3623 8r2 in 163v supply o/c
PHILIPS CP90
Field collapse - small amount of scan below No 95v to fop stage - crack in print by r3275 or r3582 3r3 o/c
PHILIPS CP90
Field collapse 2. poor contrast R3623 8r2 oc 2. preset r3944 5k oc
PHILIPS CP90
Field collapse R3623 8r2 o/c in 163v line from loptx
PHILIPS CP90
Field collapse R3623 ( 8.2Ω ) 163v supply
PHILIPS CP90
Field bounce Tda2579 timebase gen chip
PHILIPS CP90
Dull pic when connected to normal mains - ok with isolated supply Crt rimband come adrift
PHILIPS CP90
Does not start by using remote control Transistor 7730. better memory battery 1901, 2,4 v- code 4822 138 10313.