Search: philips
Results: 14210
Make Model Symptom Problem Solution By
PHILIPS CP90
Does not function Voltage +95 v not present check/replace ts 7677 (but 11 af; 4822 130 42679), check/replace ts 7673 (bc 547; 4822 130 44257) and ts 7674 (bc 328; 4822 130 44104) and replace d 6674 by byd33j (4822 130 42606) check/replace ts7727 (bc556;
PHILIPS CP90
Dead. R3668 ( 15r ) o/c.
PHILIPS CP90
Dead. C2695 ( 2.2nf ) , d6695 s/c.
PHILIPS CP90
Dead. C2679 ( 1nf 2kv ) , d6679.
PHILIPS CP90
Dead. 1.6amp fuse o/c , check for drys on loptx ect.
PHILIPS CP90
Dead with pulsing psu - the 95v ht low at 60v D6702 bzx79-f6v2 zener leaky
PHILIPS CP90
Dead with faint whistle Pri ht ok, no ht at loptr; c2619 1n5 2kv burnt & s/c
PHILIPS CP90
Dead with faint whistle Ok on dummy load. but11af loptr s/c - dry joints on chopper tfmr & loptx
PHILIPS CP90
Dead set - no st/by led or chan ind Check for osc at pins 31 & 32 tmp47c432 micro ic7840. if absent check c2934 & c2935 27pf leaky
PHILIPS CP90
Dead psu working pulsing D6610 s/c r3600 o/c d6072 ( 6v2 ) zener ( if no start up v at junction r3661 r3673 cnx62 u/s )
PHILIPS CP90
Dead power supply ok no 6v on micro ic D6733 oc
PHILIPS CP90
Dead no st/by - 95v/22v present O/c print near m13 plug/skt
PHILIPS CP90
Dead no 19v rail f1690 o/c Ic1701 tda8190
PHILIPS CP90
Dead ht rises , dies instantly R3665 , d6665 4r7 and in4148
PHILIPS CP90
Dead h.t. low 50v Check d6610 if ok suspect lopt
PHILIPS CP90
Dead but ok on dummy load with ht at 95v C2703 330µ 25v leaky
PHILIPS CP90
Dead , no stby led or chan ind , check for osc at pi C2934 - 2935 ( both 27 pf )
PHILIPS CP90
Dead - whistling - over volts prot firing Ht above normal 95v - tr7701 bc548 in error amp cct s/c
PHILIPS CP90
Dead - went off with a flash Dry joints chopper tr 7677, s/c mains rect 6657 byd14j, o/c 2a fuse
PHILIPS CP90
Dead - st/by only - ht half its normal value R3623 8r2 hi res, d6667 1n4148 o/c