Search: philips
Results: 14210
Make Model Symptom Problem Solution By
PHILIPS CTX
Wrong cols - red = purple, blue = red, grey scale ok Was degauss therm dry jointed
PHILIPS CTX
Tripping. D6590 ( byv95a ) s/c.
PHILIPS CTX
Tripping D6583 sc
PHILIPS CTX
Startup - no start up - intermittent on/off R3325 set ht pot dirty.
PHILIPS CTX
Sound - buzzing alters with picture content. Radiation - via unscreened audio lead.
PHILIPS CTX
Set dead 125v ok Check for square wave at pin 11 tda2577 if missing replace t7353 ( bf422 )
PHILIPS CTX
Raster - small raster. R3327 ( 120k ) o/c may be the set ht control.
PHILIPS CTX
Power supply dead C2323 220uf 10v
PHILIPS CTX
No/little colour Hi res joints on tda3560 chip holder
PHILIPS CTX
No timebase operation. Drys on pin 12 of loptx.
PHILIPS CTX
No sound/pic - small pic when a1 advanced R3327 120k o/c
PHILIPS CTX
No sound or picture. R3327 ( 120k ) o/c may be the set ht control.
PHILIPS CTX
No sound No lt supply to audio o/p chip - r3170 3r3 o/c
PHILIPS CTX
No picture - eht ok. R35hm ( 2.2r ) o/c.
PHILIPS CTX
No pic/sound - field collapse seen when a1 advanced 12v safety res feed to field chip o/c
PHILIPS CTX
No picture - sound ok R3584 47r fusible o/c
PHILIPS CTX
No pic - sound ok S/castle pulse low at pin 8 of tda3560; tda2577 faulty
PHILIPS CTX
No field sync 2 hi value rs in field sync cct o/c
PHILIPS CTX
No colour from cold , gradually increases Tda3650 loose in socket
PHILIPS CTX
No colour at switch on. Poor connection on tda3560 holder.