Search: philips
Results: 14245
Make Model Symptom Problem Solution By
PHILIPS CP110
Line collapse to 2" & dull raster D6610 by208 s/c, r3599 o/c on crt base
PHILIPS CP110
Intermittent ht shutdown A production change is being introduced increasing the value of r3661 from 3r3 to 6r8 (code no. 4822 116 51876). in addition, the value of c2406 is increased from 100n to 10uf 250v (code no. 4822 124 22223). reason: to reduce the incidence of spontane
PHILIPS CP110
Intermittent ht shutdown A production change is being introduced increasing the value of r3661 from 3r3 to 6r8 (code no. 4822 116 51876). in addition, the value of c2406 is increased from 100n to 10uf 250v (code no. 4822 124 22223). reason: to reduce the incidence of sponta
PHILIPS CP110
Intermittent fading of picture Check/resolder the g2 connection to the crt base panel.
PHILIPS CP110
Intercarrier-hum Replace filter 1103 (5.5 mc 4822 242 70714)
PHILIPS CP110
Int various faults - bright, pulsing, st/by, dead Chopper tfmr u/s - int internally
PHILIPS CP110
Int off briefly - esp when tapped Dy joints metalwork/heatsink by chopper & loptr
PHILIPS CP110
Int dead Trt630 bc337 line driver oc
PHILIPS CP110
Int blue screen Dry joints on decoder chip & pal delay line
PHILIPS CP110
Initially no picture; low contrast picture after some minutes. Check to see if t7672 is conducting when the fault is present. if it is check for ripple on 140 volt ht line. if a ripple is present, check/replace c2670 (4822 124 80494) and 2621 (4822 124 80494).
PHILIPS CP110
Ic7260 changed type Ic7260 changed type ------------------- a production change has been introduced changing ic7260 from tda3562/n5 to tda3566/n5. at the same time r3292, r3293 and t7267 are deleted. receivers concerned are date coded qg12940 and later. reason: alterna
PHILIPS CP110
Hum in standby; no sound after a while because ic7101 gets too hot Capacitor 2113 (470uf 35v; 4822 124 41334) goes leaky/short circuit
PHILIPS CP110
Ht volts low at 60 - 70v instead of 140v C2661 2200µ o/c in chopper control network
PHILIPS CP110
Hissing sound Chopper transformer replaced
PHILIPS CP110
Fuse 1653 blowing. Check ic7670 - cnx82a; 4822 130 10025 ic7675 - 12 volt regulator;2822 209 81726 overvoltage panel 1005; 4822 212 23099
PHILIPS CP110
Function knobs on ctv fail Check keyboard or replace ic 7840 (tmp47c432ap-8188; 4822 310 31849) or (tmp47c432ap-8189: 4822 310 31851). important: mount the metal shielding with earth to r 3276
PHILIPS CP110
Field foldover C2574
PHILIPS CP110
Field cramping D/j on l5663 or c2574 ( 680uf )
PHILIPS CP110
Field collapse Open circuit r3574 120k.
PHILIPS CP110
Field collapse Dry joints 12v reg