Search: philips
Results: 14245
Make Model Symptom Problem Solution By
PHILIPS ANUBIS A
Dead ht at only 20v instead of 95v if plug m5 rem D6555 in 5v supply leaky
PHILIPS ANUBIS A
Dead apart from whistle Loptx - tested ok on oz loptx tester
PHILIPS ANUBIS A
Dead , but11 sc. Use service kit sbc7021 pt no philips 4822 310 20491
PHILIPS ANUBIS A
Dead - ht low at 40v (95v) Tr7537 sm bc848c error sense tr leaky
PHILIPS ANUBIS A
Dead - ht being dragged down by lop stage Resistance of 20r across loptr - loptx faulty at2079/40 -tfhr7488 (cpc)
PHILIPS ANUBIS A
Bright raster with flyback lines. Break in print on crt base.
PHILIPS ANUBIS A
Blank raster no sound osd works signal fed via fro Unit in external mode check pin 18 ic7015 if high check all jumper leads around scart socket
PHILIPS AA5AB 21PT165B
Overbright raster, with flyback lines R3470 8r2 o.c. (safety resistor to 183v supply from l.o.t.)
PHILIPS AA5AB
Line collapse 680nf cap in line o/p stage low cap
PHILIPS AA5 AB
No response to r/c commands St24c02cp eeprom chip
PHILIPS AA5 AB
Line o/p tr failure Dry joints rear connector of scan coils
PHILIPS AA5 AB
Line collapse then off C2450 680nf 150v s corr cap
PHILIPS AA5 AB
Dull pic aft replacement of tda8362 or crt base components R3470 8r2 safety res in rgb ht supply o/c
PHILIPS AA5 AB
Dead with leds flashing on/off every 3 secs Eeprom fault - new st2402a made no difference, neither did lm317t reg which had no o/p - crack in print pin 1 loptx
PHILIPS AA5 AB
Dead no st/by unless line stage dis'd Loptr bu1508dx 7445 pt no 4822 130 63569; loptx 5445 pt no 4822 140 10544
PHILIPS AA5 AB
Dead - wickman fuse 1571 o/c When replaced ht low & tripping. lopt u/s. if fuse blown for no apparent reason philips say change thyristor 7481 & 3482 sm resistor 6k8.
PHILIPS AA5 AB
Dead - no line drive pin37 ic7015 tda8361 Chip faulty
PHILIPS AA5 AB
Dead - burn up &/or s/c rgb trs on crt base or ic7015 tda8362 on main pcb damaged Loptx is main suspect of this fault
PHILIPS AA5 AA
No field scan Tda3654 7401 & d6449 byd33g & 3449 400ma wickman fuse
PHILIPS AA5 21PT166B
Dead with ht loptx pri Prot 1571 o/c in series with 11v supply to 8v reg ic7567 which had s/c o/p.this feeds pin 10 multifunction chip ic7015 via l5565 which was s/c to chassis. usually caused by breakdown in loptx