Search: philips
Results: 14210
Make Model Symptom Problem Solution By
PHILIPS ANUBIS-A
Anubis-a with 3 local controls with uc tmp47c434n- Anubis-a with 3 local controls with uc tmp47c434n-3145 replaced by uc tmp47c434n-3146; 4822 209 32117 hotel mode for uc tmp47c434n-3145:
PHILIPS ANUBIS-A
Anubis-a with 3 local controls with uc tmp47c434n- Anubis-a with 3 local controls with uc tmp47c434n-3144 replaced by uc tmp47c434n-3146; 4822 209 32117 hotel mode for uc tmp47c434n-3144:
PHILIPS ANUBIS-A
Anubis-a txt with 3 local controls with uc tmp47c4 Anubis-a txt with 3 local controls with uc tmp47c434n-r131 (anubis-aac) replaced by uc tmp47c434n-r165; 4822 209 33275 hotel mode for uc tmp47c434n-r131:yes hotel mode activation for uc tmp47c434n-r131: 1.select program 38 2.press simultaneously "me
PHILIPS ANUBIS-A
Anubis-a txt with 3 local controls with uc tmp47c4 Anubis-a txt with 3 local controls with uc tmp47c434n-r133 (anubis-a ac) replaced by uc tmp47c434n-r165; 4822 209 33275 hotel mode for uc tmp47c434n-r133: yes hotel mode activation for uc tmp47c434n-r133: 1.select program 38 2.press simultaneously "me
PHILIPS ANUBIS-A
Anubis a option diode for 4 page txt Anubis a option diode for 4 page txt only for anubis a ac in service information si94.01 4822 727 20292 the text indication at option diode 6606 is wrong; it should be 4 page txt. so the option diodes for anubis a ac with latest software version r165
PHILIPS ANUBIS-A
All leds in display blinking. Check lot 5445 (4822 140 10406).
PHILIPS ANUBIS-A
After a while no picture. only sound. txt and osd are ok. Check whether dc voltage pin 11 ic7280 (tda3504) is 3v. if not, check/replace c2255 (100nf; 4822 122 33496).
PHILIPS ANUBIS-A
Afc control is slowly. station unstable. Check tuner (uv917/iec; 4822 210 10405).
PHILIPS ANUBIS-A
50 hz humm at loudspeakers in stand-by In case of a 50 hz humm at the loudspeaker in stand-by of a 3w anubis a set, it is recommended to replace: sops transformer 4822 148 60299 (dedicated for 3w anubis a sets) at itemnumber 5525. remarks: the ripple of the +13 supply voltage coming from the
PHILIPS ANUBIS-A
+ 95v is too low. Check/replace ts7445 (but11af;4822 130 42679).
PHILIPS ANUBIS B-AA
When replacing eeprom ic7685 st24c02p Default language is norwegian! & childlock (barnlas)active. to clear childlock select spec functs option c on main menu. next menu - barnlas as option a - set to fran (off). then able to set up other parameters
PHILIPS ANUBIS B-AA
Removing "demo" mode Switch on whilst holding in "vol-" & "prog+" in together.
PHILIPS ANUBIS B-AA
Led flashing with "er4" displayed Fault in txt - lines only in txt - xtal 1701 27mhz faulty
PHILIPS ANUBIS B-AA
Hor grey line over pic Field scan has osc on it - c4213 10nf o/c
PHILIPS ANUBIS BAA
Dead with pulsing squeak C2540 2200µ 16v leaky
PHILIPS ANUBIS B AA
Dead - chopper tr s/c Replaced opto ic7514 cnr50, control chip ic7500 & chopper tr
PHILIPS ANUBIS B
Works but led flashes and e4 on screen + no text 27mhz xtal on text pcb
PHILIPS ANUBIS B
No txt 27mhx xtal
PHILIPS ANUBIS B
No e-w corr R3404 47r in module 110 panel o/c
PHILIPS ANUBIS B
If ic7685 replaced set will display norwegian and Menu set "barnlas" to "fran" ( off ) then set may be reset