Search: philips
Results: 14253
Make Model Symptom Problem Solution By
PHILIPS CTO
LED indicating inverted. (on off off on) Check ts006 with leak. * 10oct97 jpba *.
PHILIPS CTO
Excess width Capacitor c507.**
PHILIPS CTO
Interference in the image Das model: with noise as if two were switching bands fit r114 acg. *anc* all models with board vst= ts050/ts053, ic100. *anc* granulated, see coil s138. * mai 95 ctr *. only channels 5 and 7 see u102. * 26jan96 anc *. see
PHILIPS CTO
Indica 18 Altered or open resistors r001, r002 and r003. ** leaky transistor ts029. *anc*. leaky capacitors c044 and c045. *anc*. indicates 18 and turns off, see timer (ic or ts). *anc*. solder short from pin 20 to 21 of the micro. * 04jan96 anc
PHILIPS CTO
Flickering image (see serr1). Capacitor c868 (4.7uf) *. Integrated IC875. * Jul 95 ctr *. d306 shorted. * 26jan96 anc *. capacitor c587. * 05nov96 fr *. check open capacitor c146. * 25Aug97 jpba *. check integrated ic151. * 18Sep97 ctr *.
PHILIPS CTO
Negative image. Check capacitors c587 (470uf) and c221 (150uf). *anc*.
PHILIPS CTO
Intermittent negative image. IC292 integrated circuit. *jun 95 ctr*.
PHILIPS CTO
Image warps like saturated agc. Integrated IC151. * Jan 95 BC *. Integrated IC875. * Jul 95 ctr *.
PHILIPS CTO
Image erased like weak kinescope. Trc, check that the s750 core has not been lost, This causes premature weakening. * 26jan96 anc *.
PHILIPS CTO
Turns pink with weak or no signal. Possible leak in capacitor c216. *anc*.
PHILIPS CTO
Becomes dark with weak or no signal. Capacitor c232 (270nf) aberto. * anc *. capacitor c221 (150uf) alterado. * anc *. capacitor c587 (470uf) alterado. * 11jan96 anc *
PHILIPS CTO
Turns gray with weak or no signal. Check capacitors c587 (470uf) and c221 (150uf). *anc*.
PHILIPS CTO
Light band in the center (i) varies with brightness/cont. Capacitor c205 without capacity. * Jul 95 jpba *.
PHILIPS CTO
Shutter effect. Td210. ** resistor r229. *out 95 ctr*. td210 fitted in incorrect position on the printout. * 26jan96 anc*.
PHILIPS CTO
Cushion effect. R513/r515
PHILIPS CTO
Distortion in the image. D301 ts050. coils s157 and s158, deficient. * mai 95 mjs *.
PHILIPS CTO
Display confuso Leaky or altered capacitor c044 (1nf). *mar 95 anc*.
PHILIPS CTO
Display off R002 open micro does not work, commands do not act, screen with drizzle and slightly dark oct 94 anc. d585 open. oct 94 anc. leaky transistor ts029 (bc548). * 02dec96 ac *.
PHILIPS CTO
Turns off immediately after turning on. Panel capacitor VST coo6 (560pf) leaking. open timer capacitor c055 (27k). * Apr 95 BC *.
PHILIPS CTO
Turn off inter. or protect (rew 3 for vcr). Fly back com solda fria s564. c507/c317/c318/c319/c325. unidade defletora u020. trimpot: r325, r871 (10k). * ago 95 anc *.