PHILIPS |
A8
|
Appears dos/menu - blinking. | When changing channels, check the remote control batteries, when weak, it causes information errors. * 11oct2000 hd * . | ||
PHILIPS |
A10
|
Dark "black" screen (see also bril4). | Check tsh (fly back) 5431. iris: symptom 111, section dfl, repair a. * 01feb2001 iws report from germany *. check integrated 7830 (tda6107q). 04May01 fcr dreux *. | ||
PHILIPS |
A10
|
Fade colors after heating. | Check the bocma on the ssp panel, if not available replace ssp panel. iris: symptom 410, vpa section, repair the. * 01feb2001 inf iws report from germany *. | ||
PHILIPS |
A10
|
Squeaky sound | Try replacing 2424 capacitors from 12nf to 11nf and capacitor 2416 from 1.2nf to 2.2nf. iris: symptom 540, section dfl, repair a. * 01feb2001 inf iws report from germany * . | ||
PHILIPS |
A10
|
So fica em stand by (power off). | Only LED is on (error 2), check vbat voltage on tansistor 7481, welding problem may occur on pin 1 from ths (fly back) 5431. iris: symptom 110, dfl section, repair d. * 01feb2001 inf iws report from germany *. check rg amplifier | ||
PHILIPS |
A10
|
Tuner with little gain | Check if the tuner is soldered. iris: symptom 341, tun section, d (chass) repair. * 02Feb2001 inf report from s'pore *. | ||
PHILIPS |
A10
|
No voltage (vo, +b, hvt, etc.). | No voltage g2 (dark screen), check tsh (fly back) 5431. iris: symptom 111, section dfl, repair a. * 01Feb2001 info iws report from germany * | ||
PHILIPS |
A10
|
No sound. (with or without image for TV, VCR). | Check 7704/7710 (bc847b). 04May01 fcr dreux *. | ||
PHILIPS |
A10
|
Noise when changing channels "plop" | Check value of the elco 3.3 uf 2705 capacitor on the panel lsp. * 14Feb2001 ehv ran meys st01/0006 * | ||
PHILIPS |
A10
|
Concave framework ( ). | Check geometry adjustment (eastwest correction). iris: symptom 338, section dfl, repair c. * 01feb2001 inf iws report germany *. | ||
PHILIPS |
A10
|
Loses memory when turned off. (unprogram) | Check capacitor 2962 4700uf (2020 021 91501), code iris 2717. * 24oct2000 ehv st00/0071 *. check ssp module. iris: symptom 264, section ctr, repair n. * 01feb2001 inf iws report from germany | ||
PHILIPS |
A10
|
Does not work in audio and video | Verificar programacao do option na pagina 99 do manual 4806 727 17235. iris: sintoma 170. 02fev2001 inf report from france *. | ||
PHILIPS |
A10
|
It doesn't work (it stays off). | Check diode 6414, coils 5474, 5475, 5476, 5478 and 5479, 7470. * 16out00 inf manual error buffer a10 *. If you have a defective PTC, check 3912. * 24Oct2000 ehv st00/0075 *. connect the 6941 cathode to the 6961 cathode, through | ||
PHILIPS |
A10
|
Blemishes in the image (lack of purity). | Check demagnetizing coil. iris: symptom 434, section crt, repair c. * 02Feb2001 inf report from s'pore *. | ||
PHILIPS |
A10
|
Turns on alone. | Device behaves strangely, check panel ssb. iris: symptom 110, section ctr, repair a (ssb). * 02feb2001 inf iws report from germany *. | ||
PHILIPS |
A10
|
LED(s) flashing. (repeatedly) | 4 times, check the 5v line, if necessary, isolate the coil 5430 and jump 9044 to facilitate its measurement. * 16out00 inf error buffer manual a10 *. check transistor fet 7421 (4822 130 63666). iris: symptom 110, dfl section, repair | ||
PHILIPS |
A10
|
Incorrect geometry on 9/16. | Readjust geometry. iris: symptom 320. * 01feb2001 inf iws report from france. | ||
PHILIPS |
A10
|
Turns off immediately after turning on. | Check 200v supply, resistors 3840, 3445 and diode 6445, 7501. * 16out00 inf manual error buffer a10 *. | ||
PHILIPS |
A10
|
Turn off inter. or protect (rew 3 for vcr). | Check deflector coil, linearity coil 5417, capacitors 2414/2416/2418/2419. * 16out00 inf error buffer manual a10 *. | ||
PHILIPS |
A10
|
Damage IC or TS semiconductor | Transistor 7410, check possible short in tsh 5431. iris: symptom 111, section dfl, repair a. * 01Feb2001 INF IWS report from germany *. |