Make Model Symptom Problem Solution By
PHILIPS A10
It doesn't work (it stays off). Check diode 6414, coils 5474, 5475, 5476, 5478 and 5479, 7470. * 16out00 inf manual error buffer a10 *. If you have a defective PTC, check 3912. * 24Oct2000 ehv st00/0075 *. connect the 6941 cathode to the 6961 cathode, through
PHILIPS A10
Blemishes in the image (lack of purity). Check demagnetizing coil. iris: symptom 434, section crt, repair c. * 02Feb2001 inf report from s'pore *.
PHILIPS A10
Turns on alone. Device behaves strangely, check panel ssb. iris: symptom 110, section ctr, repair a (ssb). * 02feb2001 inf iws report from germany *.
PHILIPS A10
LED(s) flashing. (repeatedly) 4 times, check the 5v line, if necessary, isolate the coil 5430 and jump 9044 to facilitate its measurement. * 16out00 inf error buffer manual a10 *. check transistor fet 7421 (4822 130 63666). iris: symptom 110, dfl section, repair
PHILIPS A10
Incorrect geometry on 9/16. Readjust geometry. iris: symptom 320. * 01feb2001 inf iws report from france.
PHILIPS A10
Turns off immediately after turning on. Check 200v supply, resistors 3840, 3445 and diode 6445, 7501. * 16out00 inf manual error buffer a10 *.
PHILIPS A10
Turn off inter. or protect (rew 3 for vcr). Check deflector coil, linearity coil 5417, capacitors 2414/2416/2418/2419. * 16out00 inf error buffer manual a10 *.
PHILIPS A10
Damage IC or TS semiconductor Transistor 7410, check possible short in tsh 5431. iris: symptom 111, section dfl, repair a. * 01Feb2001 INF IWS report from germany *.
PHILIPS A10
Intermittent east west correction. Check 7470 fixing spring. iris: symptom 338, section dfl, repair a. * 01feb2001 inf iws report from germany *.
PHILIPS A10
Flashing color Check contacts of the ssp module (bad fixation). iris: symptom 33x, cpa section, repair d. * 01feb2001 inf iws report from germany *.
PHILIPS A10
Branco irregular Check kinescope. iris: symptom 340, crt section, repair the. * inf iws report from germany *.
PHILIPS A10
Amplitude irregular em double window. Check 2501. iris: symptom 336, section dfl, repair a (2501). * 02Feb2001 inf iws report from s'pore *.
PHILIPS 7CM5689
Vertical flutter Resistors 3125,3134. *94 is*.
PHILIPS 7CM5689
Vertical deformed compressed parts 2406 open capacitor. * Apr 95 jo *. capacitor 2126 (470uf) open. * 02dez96 jo *.
PHILIPS 7CM5689
Vertical running (sync2). Check connection cable (pins or broken cable) oct 94 anc. integrated 7504. * jan 95 jdn *.
PHILIPS 7CM5689
Vertical with little amplitude Capacitor 2511. * anc *.
PHILIPS 7CM5689
Dark "black" screen (see also bril4). Capacitor 2355.** regulator 7108. *jan 95 en*. integrated 7504 (tda4851) pine 2. * jul 95 anc *.
PHILIPS 7CM5689
No horizontal oscillator pulse. Check altered 2544 capacitor. * 13Jul97 jo *.
PHILIPS 7CM5689
No focus. Capacitor 2128 (1000uf) aberto. * mai 95 acm *.
PHILIPS 7CM5689
Dull (see tv.screen 1) 7108