PHILIPS ANUBIS
Commands act partially or hotel mode Check possible short between terminals of the 3600 resistor, corresponding to pins 16 and 17 of the microprocessor. * 09nov95 anc *.
PHILIPS ANUBIS
With vertical bar(s) or stripes Bar on the right, change capacitor 2456, to values between 47 and 82pf/500v, there will be different results depending the value. * 07Jul96 circular psc 011/t (03/06/96) *. center bars replace tda8361 for mascara n4, perform the changes
PHILIPS ANUBIS
Burning or smoky smell. Check for possible leaks in the deflector unit. * Jul 95 ctr *.
PHILIPS ANUBIS
White with traces (or some faint color). 3300 open due to power supply overvoltage check capacitor 2512 open. *anc*. check resistors 3308 (100Û), 3469 and 3470 (3Û9), possibility of being open. * 2set96 anc *.
PHILIPS ANUBIS
Appears in the / menu, however, without an image. Capacitor 2208 leaking. * Jul 95 jpba *. resistor 3209 (12Û) open. * 23jan98 jpba *.
PHILIPS ANUBIS
Activating crowbar. See capacitor 2512 open on board set 94 anc. 3530 resistor open. * mai 95 ctr *. diode 6446. * mai 95 ctr *. leaky 7636 transistor. * 26Feb96 anc *.
PHILIPS AK701
Doesn't read Hf adjustment 1.2 vpp.** cdm laser unit.**
PHILIPS AK630
Noisy or crunching sound Memoria um6264 e decoder set 94 eag.
PHILIPS AK630
Squeaky sound Integrated 7031. * mai 95 ctr *.
PHILIPS AK630
Jumping track Set to 118 7830/
PHILIPS AK630
Loses reading with small touch. Check cdm and integrated 7840. * 02dec96 esc *.
PHILIPS AK630
Right channel doesn't work Resistor 3872. * mai 95 ctr *.
PHILIPS AK630
Doesn't read Broken track on tda 8808 pin 20 and pin 28 track from tda 8809. * jul 95 esc *. replace power supply diodes with possible intermittency. * 10oct97 lt *.
PHILIPS AK630
Doesn't open drawer Resistor 3962. resistor 3949. * mai 95 ctr *.
PHILIPS AK630
Focus does not adjust. See track of pin 28 of the tda8809 and pin 20 of the tda8808. * Jul 95 esc *.
PHILIPS AK630
Flashing display Capacitor 2600. * mai 95 ctr *. replace power supply diodes with possible intermittency. * 10oct97 lt *.
PHILIPS AK630
Display confuso Verify 5851 resonator 8.46 mhz as cold solder. * Dec 94 eag *.
PHILIPS AK630
Turn off inter. or protect (rew 3 for vcr). Check diodes: 6600/01/02/03. * mai 95 ctr *.
PHILIPS AK630
Damaging laser unit Solder short between pins 24 and 25 of the tda8809 (7830). * sea 95 aac *.
PHILIPS AK630
Turns off display after starting reading 7702