PHILIPS 21GR7560
When turning off, a streak remains on the screen Check sops module, do not use a 28" plate for a 21" one. * Jan 95 jdcc/ab *.
PHILIPS 20PV471
Does not open vertically R3531 (56r) open. *18Sep98 CP160*
PHILIPS 20GX1656
Intermittent sound (crashes, hiccups). Verificar solda do smd (2k) 3801. * 20dez95 ctr *.
PHILIPS 20GX1656
No sound. (with or without image for TV, VCR). Solda fria no resistor smd 3801. * 20dez95 ctr *.
PHILIPS 20GX1656
No sound on phone output. Verificar plug do fone. * 21ago96 ctr *.
PHILIPS 20CT6657
Li or lii(sap) led weak or off. Capacitor c041, or integrated ic227 (7426). * 26jan96 anc *.
PHILIPS 20CT6558
Volume doesn't go down Escape no diode d038. * abr 95 anc *.
PHILIPS 20CT6558
Screen half dark or noisy. Dark left side, capacitor c583. * 26jan96 anc *.
PHILIPS 20CT6558
Screen darkens on scan. Integrado ic035. * ago 95 anc *. capacitor c587 sem cap. * 26jan96 anc *.
PHILIPS 20CT6558
Intermittent sound (crashes, hiccups). Capacitor c014, c015 and integrated IC12. * 11jjan96 anc *.
PHILIPS 20CT6558
There is only sound on a stereo channel. Check integrated circuit ic227 (sn7426). * Apr 95 BC *.
PHILIPS 20CT6558
No sound. (with or without image for TV, VCR). D010. * 94 anc *. ic226/ic012. * 94 anc *. ts005. * 94 anc *. co64/c229. 94 anc *. capacitor c064 com fuga. * 26jan96 anc *.
PHILIPS 20CT6558
Sem som em lii (sap) U203 veja 20ct6557. jul 94 anc.
PHILIPS 20CT6558
No image in av, or dark. Capacitor c023 with leakage. * 26jan96 anc *.
PHILIPS 20CT6558
Don't search Possible leak in the li/lii switch. * May 95 BC *.
PHILIPS 20CT6558
Does not accept remote commands Possible leak in the li/lii switch. * mai 95 anc/ctr *.
PHILIPS 20CT6558
Flashing stereo led. Altered s203 coil. anc
PHILIPS 20CT6558
Li or lii(sap) led weak or off. S3 cable with poor contact. * 26jan96 anc *. leaky capacitor c657. * 26jan96 anc *.
PHILIPS 20CT6558
Interference not som Generally occurs when the unit has been replaced varicap, see input coil adjustment at the top of the varicap. * Apr 95 BC *. a109 cable with broken wire. * 26jan96 anc *.
PHILIPS 20CT6558
Indica 18 Check integrated ic035. * 18Sep97 ctr *.