SAMSUNG CI623CN
Field collapse Tda8350q s/c ; r307 10r 1/2w fusible o/c
SAMSUNG CI6230WN
Won't come out of st/by when cold C806 100µ 25v
SAMSUNG CI6230WN
Tripping C56 2u2 250v , c590 on tube pcb use 450v types
SAMSUNG CI6230WN
Tripping Check c560 2.2mfd 250v crt base , replace c590 as well. ( to confirm - remove crt base connector at plug near lopt )
SAMSUNG CI6230WN
Pulsing psu & tripping C560 2µ2 250v on crt base - also check c590 - remove plug by loptx to crt base to check this fault
SAMSUNG CI6230WN
No r/c operation Micro ic701 had developed internal s/c which made prot line go low- pca84c840/062
SAMSUNG CI6230WN
Field chip has short life Fit a 470n cap from pin 5 of the chip to deck and replace pj28 with a 10 mh choke, check elect caps, give no guarantee and hope!
SAMSUNG CI6230WN
Dead with squeal C416 2µ2 250v in lop supply
SAMSUNG CI6230 UM88MT-1
Filed collapse When replacing tda3654 fop chip also replace wire link pj28 (from pin 5 chip) with 10µh inductor pt no 2701-001040 & fit 470nf polyester cap pt no 2305-000407 between pins 4 & 5 tda3654 as close as poss to chip to prevent reoccurence
SAMSUNG CI6230 U88MT1
This set was dead , with just a high pitched squeal C416 ( 2.2 , uf , 250v ) was short-circuit. it decouples the supply to the line output stage.
SAMSUNG CI6230 U88MT1
Partial or complete field collapse , replace ic301 Add 1n4148 from pin 9 ic301 to pin 3 ic 301 anode to pin 3 add 1n4148 from pin 3 ic301 , anode to ground add 12pf ceramic fr
SAMSUNG CI6230 U88MT1
Odd video - no colour Check 12v supply from reg.
SAMSUNG CI6230
St/by only C808 & 806 100µ 25v
SAMSUNG CI6230
No sound - ok via scart Audio in at tda8415 ic601 ok but no o/p - no osc due to 10mhz xtal being u/s
SAMSUNG CI6230
Field non lin and short pic 4
SAMSUNG CI6230
Dim heaters, non lin field, hum bar on cols - all line derived supplies low C560 4.7uf @ 250v & c590 2.2uf @250v on crt base
SAMSUNG CI6230
Dead C416 2µ2 250v blasted - check d814 s/c ru4am - byw95c does
SAMSUNG CI6229T P72
No pic unless a1 advanced - looks like failing mono tube C416 2µ2 250v ht decoupler
SAMSUNG CI6229T
Int dead or does not switch on from cold Replace c806 100mfd25v
SAMSUNG CI6229T
Field collapse - repeat failure of fop chip Mod by removing link pj28 and in it's place fit a 10uh choke. also add a 470nf 100v capacitor from pin 5 of ic301 to earth. pj28 is the 26volt supply to the field ic and this rail suffer's from spike's.!