Search: samsung
Results: 3847
Make Model Symptom Problem Solution By
SAMSUNG CI1213R
Dead - psu starts up then shuts down L110 in ht feed to lop stage dry joint
SAMSUNG CI1212R
Failure to start No start up volts to pin 8 ic105 micro. - chip faulty tmp47c433an3842
SAMSUNG CI 3312 CI5013
High ht on b1 ( 125v ) line , causing q402 to fail Check r807 ( 11k ) pt no. samsung 31018177113 - reason : no ip. on pin 3 ic801 for control amp
SAMSUNG CF5344N
Field collapse & no sound 12v supply to reg missing - cracks in print
SAMSUNG CB7230ZN P72
Field collapse Tda3654 fop chip (tried 3 b4 found one that would work)
SAMSUNG CB6833W
Dead psu C808 100µ 25v
SAMSUNG CB5373
Repeated blowing of smr40200 Bu508af on a hybrid panel can be used instead (leave pins 1 & 5 dis'd) & change hiso169b, 150v avalanche diode, 33µ cap
SAMSUNG CB536Z P45S
Rolls aft 2 hrs R210 240k
SAMSUNG CB336F
Sound will not turn down. R604 ( 1r ) o/c.
SAMSUNG C1541ZG
Whistle on sound Change rc11 from 1uf - 10uf
SAMSUNG C1537V
No vis , just blank raster Tuner faulty ( a different tuner is supplied. )
SAMSUNG C1537V
Field roll when changing stations Change c307 0.47mfd , 50v tant
SAMSUNG C1537V
Failure of q901 2sc3552 at switch on Replace r910 270k
SAMSUNG C15012Z
Drifts off tune R116 ( 120k )
SAMSUNG C13312Z
Volume stuck ( max ) osd does change R625 ( 10k ) open
SAMSUNG C13312Z
No tuning 0-30v line not varying 05 ( 10k ) open
SAMSUNG C1210R
St/by only 11v ht line rises to 2.5v then off. d106 fr304 efficiency diode in lop stage s/c
SAMSUNG C1210R
Blank white raster with fb lines Crt cath volts low due to c512 22µ 160v in 115v supply dried up
SAMSUNG C!3312Z
Field collapse R307 33k hi res
SAMSUNG BT309K
Blank white raster. Detector can in if strip.