Make Model Symptom Problem Solution By
SAMSUNG CI3373
Faint pic Set to 'mild' on handset - reset to normal
SAMSUNG CI3373
Dead with fuse blown Check zd8011 for s/c
SAMSUNG CI3352XT P68C
Dead with loptr s/c Check 125v ht line before replacing loptr q402 2sd1651 - should be 125v. if higher c852 470µ 16v on psu pri is usually the cause
SAMSUNG CI3352AT P68
Slow to change chan, go into txt & analogue functs Tx01 27mhz xtal
SAMSUNG CI3352 P68
Dead - ic801 sdh209b faulty When replaced, 125v ht was 170v due to c852 470µ 16v faulty
SAMSUNG CI3351X
Will not tune in. Dz824 ( 33v ) leaky , r822 ( 15k , 2w ) o/c.
SAMSUNG CI3351X
Stuck in standby. Rd201 ( 5.6v zener ) leaky , ic802 ( mc7808 ) s/c.
SAMSUNG CI3351X
St/by only Rd201 5v6 zener leaky; ic802 mc7808 s/c
SAMSUNG CI3351X
No tuning Dz824 33v zener leaky; r822 15k 2w o/c
SAMSUNG CI3351X
No sound or raster - standby led on. D402 ( kf105 ) s/c , r826 ( 1r ) o/c , c908 ( 1u f , 250v ) on crt base o/c.
SAMSUNG CI3351X
No sound or raster - st/by led ok D402 kf105 s/c; r826 1r o/c; c908 1µ 250v o/c - on crt base
SAMSUNG CI3351X
No red tho' osd ok Ic501 tda4661
SAMSUNG CI3351X
No red osd coect colour Ic501 tda 4661 may also cause loss of blue
SAMSUNG CI3351X
No raster - sound ok. R925 ( 4.4r , 2w ) o/c.
SAMSUNG CI3351X
No raster - sound ok R925 2r4 2w o/c
SAMSUNG CI3351X
No colour int. Loose connector bcgnd on crt panel.
SAMSUNG CI3351X
Interference on pic - int Aquadag earthing loose
SAMSUNG CI3351X
Int loss of col Loose conn bcgnd on crt base
SAMSUNG CI3351X
Int interference on picture. Aquadag earth lead loose.
SAMSUNG CI3351X
Int going into search tuning mode. Rx01 ( 10mhz ) faulty.