SAMSUNG CB5373
Repeated blowing of smr40200 Bu508af on a hybrid panel can be used instead (leave pins 1 & 5 dis'd) & change hiso169b, 150v avalanche diode, 33µ cap
SAMSUNG CB536Z P45S
Rolls aft 2 hrs R210 240k
SAMSUNG CB336F
Sound will not turn down. R604 ( 1r ) o/c.
SAMSUNG C1541ZG
Whistle on sound Change rc11 from 1uf - 10uf
SAMSUNG C1537V
No vis , just blank raster Tuner faulty ( a different tuner is supplied. )
SAMSUNG C1537V
Field roll when changing stations Change c307 0.47mfd , 50v tant
SAMSUNG C1537V
Failure of q901 2sc3552 at switch on Replace r910 270k
SAMSUNG C15012Z
Drifts off tune R116 ( 120k )
SAMSUNG C13312Z
Volume stuck ( max ) osd does change R625 ( 10k ) open
SAMSUNG C13312Z
No tuning 0-30v line not varying 05 ( 10k ) open
SAMSUNG C1210R
St/by only 11v ht line rises to 2.5v then off. d106 fr304 efficiency diode in lop stage s/c
SAMSUNG C1210R
Blank white raster with fb lines Crt cath volts low due to c512 22µ 160v in 115v supply dried up
SAMSUNG C!3312Z
Field collapse R307 33k hi res
SAMSUNG BT309K
Blank white raster. Detector can in if strip.
SAMSUNG BT309K
Blank white raster Detector can in if replaced
SAMSUNG BT110
Servicing the samsung model bt110 See tv mag aug 1993
SAMSUNG BT110
No tuning R128 6k8 feed res to 33v reg o/c
SAMSUNG 5052X P64
Raster blanked off No y signal out of jungle chip to timebase - r420 22k feeding line pulses to jungle chip o/c
SAMSUNG 3373Z
Off with a bang C805 2200pf 800v leaky - had shattered fuse and caused blackening of pcb - under psu reg heatsink
SAMSUNG DT15LS7L / DT15VSPN - 550S / 5
Image distortion Replace: r415 from: 12r to 15r