Make Model Symptom Problem Solution By
SHARP C-2006A
Dead C707, c711 and/or c710
SHARP 37 AM 12 S
Expanded colored lines on the screen C 713 = 1000μF 16 volt
SHARP VC - A 43
Doesn't start Power supply c 913 = 47 uf Sub c913 = 47 μF
SHARP 54AM 12S
CA1
Screen with expanded lines C 712 = 1000uf 16 volt no capacity Sub c712 = 1000μF 16volt
SHARP DV 5432 S
Deco 5
LED flashes green and does not turn on or takes a long time to turn on and off R 751 = 0, the expulsion number Sub r751 = 0,33r
SHARP DV5432
Doesn't start Lede verde centila C754 = 470μF without capacity
SHARP 54AM 12S
CA1
Screen with expanded lines C 712 = 1000uf 16 volt no capacity Sub c712 = 1000μF 16volt
SHARP DV 5432 S
Deco 5
LED flashes green and does not turn on or takes a long time to turn on and off R 751 = 0, the expulsion number Sub r751 = 0,33r
SHARP VC - A 43
Doesn't start Power supply c 913 = 47 uf Sub c913 = 47 μF
SHARP DV5432
Doesn't start Green LED blinks C754 = 470μF without capacity
SHARP 54DT25S
When turned on it oscillates out of frequency Sub c604 = 220μF c622 = 220μF
SHARP 54DT25S
When turned on it oscillates out of frequency Sub c604 = 220μF c622 = 220μF
SHARP C-1453
Turned off When placing the multitest tips between base and emitter, on the rx1 scale (tip, positive on the base) of q-707 (2sc 144) if it lights up changing channels alone while keeping the tips connected. the defect is a shorted channel sensor, or the diode comb at the micro input with a shorted diode. check this
SHARP C -1491B
With drizzle without channels Pin 2 of the plug (n) was unsoldered. model c-20st58 defect: no image with the screen off and beeping. The q-602 c2482 transistor was replaced, it looked good but it was the defect.
SHARP C -1453
Blue screen with feedback lines, or red, or green Blue q-853 c2229 r-866 18k, red q-851 r-868, green q-852 r-860.
SHARP C 2035B
And the same defect as the previous one but this one is not processed automatically, it is easier to understand that the defect is due to aft. This TV also had the sound turned down. Aft coil out of calibration and also the sound discriminator coil due to corrosion on the internal capacitor.
SHARP C 20R12
Blue screen when asked to tune it goes over the channel if you touch the volume button until the information on the screen turns green, the moment the tuning goes through the channel it stops and the image looks like it is with the a.g.c. saturated and out of sync. Aft coil with damaged internal capacitor.
SHARP C - 1404A
Off but the tube filament lights up there is no sound The printed circuit track is broken due to heat, between the d-602 pin and the c-630 pin.
SHARP C-20ST58
No image with the screen off and beeping The q-602 c2482 transistor was replaced, it looked good but it was the defect.
SHARP C-1491B
Screen lights up when there is a lot of drizzle, it doesn't pick up channels Cold solder on the circuit.