Search: sony
Results: 20088
Make Model Symptom Problem Solution By
SONY KV2000
Power supply. C612 ( 3 3u f , 25v )
SONY KV2000
Flyback - lines - over two thirds of pic. C827 ( 4 7u f ) ht decoupling o/c.
SONY KV19XMTU
Tuning drift & wont tune in new chans Dry joints if unit
SONY KV1810UB MK2
Grainy picture. Q211/212 plus associated components , tuner.
SONY KV1810UB MK2
Frame - slight field non-linearity. C520 ( 10u f , 16v ) can use two 22u f back-to-back.
SONY KV1810UB MK2
Frame - height varying. Thermistor th501 , check field tb presets.
SONY KV1810U
Frame - height reduced. C523 , c503 , c504.
SONY KV1810U
Failure of gcs. C523 ( 22u f , 400v )
SONY KV1810
Left side too dark right side too bright. C543 ( 4.7u f , 350v ) o/c on field/line tb panel.
SONY KV1800U
Frame - jitter - intermittent. Q507 noisy.
SONY KV1602
Horizontal green lines in picture when hot Remove capacitor c816 33pf.
SONY KV14V5U
Trips Loptx
SONY KV14V5U
Stuck on bbc1 aft few mins & then blank raster on chan change & no osd Dry joints tuner
SONY KV14T1U BE4
Bright white raster Check conns/cracks around loptx
SONY KV14T1U
Sound at max Replace tact sws pt no sw01634
SONY KV14T1U
Pic fades with flaring at sw on Crack by loptx (to crt htrs?)
SONY KV14T1U
Led flashing 6 times with a break of 1 sec between every 6 flashes. Replace lopt (konig fat30489 from seme)
SONY KV14T1U
Dead R614 0r47
SONY KV14M1D
Int dead - goes into prot mode Tda8139 int
SONY KV14LT1U
Reverts to st/by aft few mins R618 270k hi res