Make Model Symptom Problem Solution By
SONY XRC190
Rotary mode switch s901 fails, causes damage to reel bracket Mode switch fails prematurely causing reel bracket assy to bedestroyed. when reel bracket is replaced also replace rotary mode switchas well (p/n 1-692-885-11). this will prevent intermittent rotaryswitches from eating the reel bracket assy.this fpr was
SONY XR6450
Rotary mode switch s901 fails, causes damage to reel bracket Mode switch fails prematurely causing reel bracket assy to bedestroyed. when reel bracket is replaced also replace rotary mode switchas well (p/n 1-692-885-11). this will prevent intermittent rotaryswitches from eating the reel bracket assy.this fpr was
SONY XR6450
Slow tape speed (found main motor m901 defective) Cassette runs slow. tried adjusting pontentiometer in motorto no avail.
SONY MDXC150
Spindle motor does not run (resoldered ic201) Clv would not spin. no voltage or signal from ic302 pin 2 &44. ic302 was getting its error signal (pin 41) from ic301 pin 39.this was a tough problem because this is the signal for both directionand initial kick spin of the clv.
SONY EXR21
Rotary mode switch s901 fails, causes damage to reel bracket Mode switch fails prematurely causing reel bracket assy to bedestroyed. when reel bracket is replaced also replace rotary mode switchas well (p/n 1-692-885-11). this will prevent intermittent rotaryswitches from eating the reel bracket assy.this fpr was
SONY CDXU300
Mechanism jams (found m501 and m502 were defective) Elevator and loading mech work very slow you will notice ahum on audio. when you take the unit apart to test, unit works fine. ifyou measure voltage from power supply to mechanism chassis when loadinga disc you measure 4.5v. if you connect unilink gro
SONY CDX71RF
Unit skips (found low rf level, replaced optical pickup) Unit skips. found low p-p output from laser, and waveform wasnot very clear.
SONY CDX71
Does not load discs (replaced lower roller assy) Unit would not load any cd's. lower roller assy was worn outand slipping on the roller gear assy.
SONY CDX51RF
Skipping on outer tracks (found clv motor m902 defective) Skipping on outer tracks (intermittent). m902, part numbera-3252-844-a, wobbles. this makes focus servo work overtime andcauses skipping some disks skip more than others.
SONY CDX5090
Discs will not load (found d801 and d802 defective) Cd will not load.
SONY CDX5080
No tuner function on either am/fm (found d410 defective) No tuner function on either am/fm. found d410 shorted. thisdiode regulates the base of q418 tuner b+ switch.
SONY CDX4090
No audio (found audio amp ic303 defective) No output.
SONY CDX4090
No audio (found q594 shorted collector-emitter) Not audio.
SONY GDM20SE1
No picture, no hv, geom light on Unit has no high voltage geom light is on. power save andpower lights are flashing.
SONY GDM17SE1
No picture, no hv, geom light is on Unit has no high voltage. from light is on. power save and power light are flashing.
SONY CPD15SF1
Prevent crack on d board Because of heat sink for ic502 part 403555501 is notavailable in stock.
SONY CPD15SF1
Hv shutdown after turn on, geom light on
SONY WCS990
Unit dead with duracell batteries Unit is dead with duracell aaa batteries. will work o.k. withother manufacturers batteries. the problem is that the positive batteryterminal on the outside battery compartment does not make contact withduracell batteries because it is not wound up enough
SONY TCDD7
Intermitant loss of audio - tightened loose roller set screw Customers complaining of loss of audio and dropouts. unitsare coming in out of alignment and set screws for the roller guides loose. this is the 5th set that has this symptom.
SONY CFD600
Disc jamming Cd mechanism jammed. jam caused by solenoid not operating.q810/solenoid drive had shorted and burned surrounding pcb. we are receiving a number of reports concerning the cfd 600 series.problem is intermittent disc jamming. on some the problem appear