Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
TAAX301
|
No audio, video stays lit - replaced ic102 | No audio, video stays lit. defective ic102. | ||
SONY |
STRG1ES
|
No display on front panel - replaced open r783 | Unit has open resistor r783. unit has no display only soundfield. | ||
SONY |
STRD615
|
No power - traces on transformer board and opened | Traces on transformer board from connection cnp807 openedfor no apparent reason. | ||
SONY |
STRD615
|
Intermittant loss of front speakers - replace ic300 | Intermittent loss of functions or loss of front speakers.second unit in week same problem. -hq comments: replaced ic300, surround control, problem resolved. | ||
SONY |
STRD611
|
L & r channel output is unbalanced in dolby surr | A speakers become unequal out when unit in surround mode,which is also affected by type of surround mode. is this normal orsoftware? -hq comments: are you supplying a dolby signal to test the unit or is itstereo. if you are using a stereo signal the d | ||
SONY |
STRD315
|
Manual correction required/r726 - use p/n 1-217-156-00 | Need .22Ω, 5 watt resistor, received .22Ω, 2 wattresistor. wrong part listed in service manual for resistors r726, r727,r776, r777. need correct part number. -hq comments: as per ken budoff, 1-217-156-00 is the correct p/n forthe .22Ω 5 watt re | ||
SONY |
STRD2090
|
No onscreen display, replaced ic203, same problem | Unit has no video display and on screen board was replaced.servicer thinks the problem must be ic203. ordered p/n 875908762 whichis an hd6433258a37f. they rec'd a hd6433258f10. there is no informationto indicate that this is a good sub. any ideas ot | ||
SONY |
STRD2070
|
No sound after replacing digital 1 pcb | No sound after replacing digital 1 pcb. found cnp301 wasreversed on pcb. i replaced pcb 2 times and after 2nd time, i foundconnector reversed on both pcb's. this is a factory problem found only onthe replacement board. reversing the connector restor | ||
SONY |
STRD1011S
|
Intermittent pop left ch, left meter reads max - repl ic404 | After warm up there is a slight pop from left speaker. leftside of eq display will go max. | ||
SONY |
SSU530
|
Distorted bass | Distorted bass. found that the woofer construction is suchthat the center becomes separated from the surrounding cone at the firstridge. the paper becomes very weak and starts to tear. see drawing onrear of this report. this enclosure is a ported ty | ||
SONY |
SRS88PC
|
No audio - resoldered q101 | When power button was power button was pushed, power ledwouldn't light up. | ||
SONY |
HCDH51M
|
Dead set - r901 opens due to s517 short | On some units the mounting position of s517/clock displayswitch is such that when it is pushed, the ground side of the switch cancome in contact with jw501. this jumper wire is on the 5v buss which thenshorts to ground and opens the fusible resistor, r9 | ||
SONY |
HCDH50
|
Plays track for about 30-50 sec then skips backward | Verified customer complaint unit would skip backwards on anytrack selected, inner or outer track. | ||
SONY |
HCDC33
|
Clock not functioning - resoldered r910 | Real time clock oscillator (32 khz) did not run. found nosolder one side of r910. | ||
SONY |
HCDC33
|
Cd mech jammed - realigned mech | Cd will not open, close, play because mechanism is jammed dueto unit shipped with no transit screws for unit. also could use extension cable from cr105 of cd board to cn801 of front cd control board. | ||
SONY |
DTC1000ES
|
Burst of noise at edit points - adjusted t/u tension | Unit fails to erase old material at edit points. if you recordpause, then go back to record again, you will hear the old material forabout 1/2 second when you play back the tape. it appears that the tape isnot making adequate contact with the drum in the | ||
SONY |
CDPC545
|
Unit jams - replaced ic551 | The unit worked fine until the exchange function was selected. the door would open but the tray would not rotate. the unit would thenlock up and not respond to any command. | ||
SONY |
CDPC345
|
Timing appears to be a problem - resoldered main board | The unit acts very erratic, i.e. the drawer opens fast orslow, timing seems off, but when done by hand (unpowered) timing is ok. | ||
SONY |
CDPC235
|
Won't read complete disc - resoldered ic101 | Unit would not read a full disc. | ||
SONY |
CDPC215
|
No mechanical action | Original problem, no mechanical action. ic401 was replacedand now all functions work except the next disc will not be played. thenext disc will be selected and it will chuck but will not spin. a newboard, with the latest ic, was ordered and it acts the s |