Sony Repair Tips
Search: sony
Results: 20092
Results: 20092
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
KV20S10
|
Glow on screen after set is turned off | Unfocused glow on the screen after the unit is turned off. | ||
SONY |
KV20M10
|
Glow on screen after set is turned off | Unfocused glow on the screen after the unit is turned off. | ||
SONY |
KV19TS10
|
Pix is jittery after few days, replaced c503 | Unit looses vertical sync after warm up. discovered defective capacitor c503. | ||
SONY |
KV13VM20
|
Shut down, replaced zd1822 and f1803 | The unit would start to oscillate and then immediatley shutdown. the problem was caused by zd1822 shorting. fuse 1803 on the 12volt line also opened. zd1822 is over voltage protection for the 12 voltline. with the 12 v line inoperative, the feedback | ||
SONY |
KV13VM20
|
Very dark picturee, open g2 resistor r1915 | Picture was very dark with just a little chroma showing through. check g2 voltage at crt and found r1915 is open. | ||
SONY |
KV10FMR20
|
No power, replace power supply components, see s/b 200 | No power. | ||
SONY |
KP41EXR96
|
Shut down,unit goes into protect,replace shorted c1718 d pcb | Shut down. found unit going into protect. | ||
SONY |
FDT5BX5
|
Color control does not work, replaced r381 | Color control does not adjust. | ||
SONY |
FD525
|
No high band vhf, replaced ic101 | Unit will not tune any high vhf channels. | ||
SONY |
FD525
|
Poor pix and signal, replace jungle ic | No signal, poor video and agc not stable on all ch/no high ch. | ||
SONY |
AA CHASSIS
|
Volume control bar on full, normal when menu vol fixed | Volume bars were at max. could not decrease the bars. | ||
SONY |
FD230
|
No pix with batteries or ac adapter, replaced ic601 | Unit has sound but no picture with either batteries or ac adapter. discovered the 4.2v regulator was not working. | ||
SONY |
SPPX90
|
Defective display/operation | We are seeing continuous problems with defective sub keyswitches. this causes some buttons not to work. unit either woulddisplay ppp or search for 30 secs before answering call. the sub keyswitch pad appeared to have suffered a static discharge and a pun | ||
SONY |
SPPX50
|
Defective display/operation | We are seeing continuous problems with defective sub keyswitches. this causes some buttons not to work. unit either woulddisplay ppp or search for 30 secs before answering call. the sub keyswitch pad appeared to have suffered a static discharge and a pun | ||
SONY |
SPPA250
|
Part numbers reversed | The service manual states the ac adaptor for model sppa250is 146683421. this is incorrect. the sppa250 is cream and the ac adaptorlisted is black. the correct ac adaptor for sppa250 is 146683411. modelsppa450 indicates part number 146683411 which is | ||
SONY |
ITA750
|
Can't playback messages - clean icm protect switch s204 | Unit would not play back messages. problem was caused by ashorted s204/icm protect switch. when in off position, some debris insideswitch was keeping it on. unit required a security code to playback. | ||
SONY |
ITA200
|
Unit would only play back one message | Unit would take several messages from incoming calls. whenplaying back messages the unit mechanism would only playback one messageeven though display showed 2 or 3 messages. | ||
SONY |
SSCM354
|
Unit dead dc/dc convertor bad- replace | Unit dead, dc/dc convertor bad. serial number 16981 and11276 also included. | ||
SONY |
CKV20EXR
|
No audio on v1 input, replaced d905 on "u2" board | No audio on v1 input. found shorted diods d904 and d905. | ||
SONY |
TAAV521
|