Search: sony
Results: 20077
Make Model Symptom Problem Solution By
SONY KV32XBR15
New mcb, v produced white child picture., jumper r1139 miss Original problem was many white speckles on otherwisenormal child picture. mcb, v was substituted from a working set and theproblem eliminated. new replacement mcb, v produced a white child pix,washed-out child video with no detail. a second replaceme
SONY KV32XBR10
Hor. output failure, see sb 161r1 Dead hor. output q-503 failed.
SONY KV32TS46
Red and green color distortion, replaced the "p" board. Red and green colors distorted, blue ok. the chroma signalbecame distorted in passing through the p board. replacement of thatboard corrected the problem. -hq comments: the p board is the pip circuit board. chroma issupplied to ic3204/pin 39 and exits
SONY KV32TS36
Vibrating sound from inside cabinet, replaced yoke Vibrating sound from back of tv.
SONY KV32TS20
Distortion in picture, replaced yoke Distortion on top and bottom of picture. similar to flagwaving. yoke was running hot. found defective yoke. the yoke did checkok on the z meter.
SONY KV32HSR10
Hor. output failure, see sb 161r1 Dead hor. output q-503 failed.
SONY KV29XBR85
Hor. output failure, see sb 161r1 Dead hor. output q-503 failed.
SONY KV27XBR65
Hor. output failure, see sb 161r1 Dead hor. output q-503 failed.
SONY KV27XBR60
Hor. output failure, see sb 161r1 Dead hor. output q-503 failed.
SONY KV27XBR55
Hor. output failure, see sb 161r1 Dead hor. output q-503 failed.
SONY KV27XBR51
Timer mode misoperation/ mistake in owners manual Customeris in the video mode. they set up the timer to turntheir tv on at a preset time and channel. when the unit comes on thepicture is from the preset channel, but the audio is still in the videomode. -hq comments: customer owners manuals have a mist
SONY KV27XBR51
Hor. output failure, see sb 161r1 Dead hor. output q-503 failed.
SONY KV27XBR50
Hor. output failure, see sb 161r1 Dead hor. output q-503 failed.
SONY KV27XBR15
Hor. output failure, see sb 161r1 Dead hor. output q-503 failed.
SONY KV27XBR10
No pin cushion adjustment, replaced q505 Can't adjust pin cushion with remote (service mode).
SONY KV27XBR10
Hor. output failure, see sb 161r1 Dead hor. output q-503 failed.
SONY KV27V55
High pitch squeal, resoldered shield on the hor. output Could not find the power supply of the high pitch noise. tried rtv on all the usual places. -found: solder connections on the horz output heat sink. had broken lose. resoldered the heat sink and the squeal stoped. -hq comments: firs
SONY KV27V55
Distorted picture, replaced jungle ic301, 8-752-059-67 Picture is distorted and noisy. traced problem to defectiveic301.
SONY KV27V55
Remote rm-y119 does not spring open, replaced remote Remote does not spring open when button is pushed.
SONY KV27TW75
Trash in pip picture, replaced "v" board Pip window comes up but only trash in window.