Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
SLVP30
|
Service bulletin no. vid0122r1: ic-501 substitution | Per bulletin vid0122r1, either ic substitution will work.part number, 8-752-814-77, has a dealer cost of $28.91. part number,8-752-815-32, has a dealer cost of $65.32. both are in stock in kansascity. -hq comments: thank you for the information. | ||
SONY |
SLV70HF
|
Service bulletin no. vid0122: ic-501 substitution | Per bulletin vid0122r1, either ic substitution will work.part number, 8-752-814-77, has a dealer cost of $28.91. part number,8-752-815-32, has a dealer cost of $65.32. both are in stock in kansascity. -hq comments: thank you for the information. | ||
SONY |
SLV50
|
Service bulletin no. vid0122r1: ic-501 substitute | Per bulletin vid0122r1, either ic substitution will work.part number, 8-752-814-77, has a dealer cost of $28.91. part number,8-752-815-32, has a dealer cost of $65.32. both are in stock in kansascity. -hq comments: thank you for the information. | ||
SONY |
SLV555UC
|
Clicking sound from capstan motor | Noise coming from plastic gear on capstan motor (ref. no. 386)page 156 of service manual. i have seen about two a month since this unitwas released. | ||
SONY |
CPD1320
|
No picture | High voltage, no picture. please refer to s/m supplementnumber 2. pressure from the cabinet bottom is causing the plastic spine topush diode d-402 against pin 7 of ic-400. also applies to serial number5000850.solution: clip pin 7 of ic-400 to remove the | ||
SONY |
KV32XBR10
|
High voltage at zero beam current= 29.5kv | What is the high voltage at zero beam current for 32 inchcrts? -hq comments: normal operating high voltage (cut off) should be 29.5 kv. | ||
SONY |
PVM1910
|
Horizontal unlocks | Asc reports two units that lose horizontal lock. | ||
SONY |
TCWR820
|
Mechanical grinding noise - deck doesn't operate | Received a couple of units with gear grinding noise.disassembled deck could not find anything wrong. reassembled and problemstill exists. found piece of rubber bottom of unit and investigated whereit went. | ||
SONY |
KV27XBR50
|
Sm states units has pip, this is inacurate information, | Service manual of this model, pages 9, 10, 11 containsinstructions on pip feature whereas this model does not have it. pleaseexplain. -hq comments: you are right, this is a mistake in the manual. | ||
SONY |
D66
|
Unit skipping | Unit is skipping. | ||
SONY |
D66
|
Disc would not spin - spindle motor jammed | On this unit spindle motor jammed down too low and will notspin. on two other units, spindle motor makes a slight clicking noise andtracking error waveform does not look too good. | ||
SONY |
CDPC700
|
Cloudy lens in new kss-150a | Pulled a new optical block out of stock and noticed it had acloudy lens. i did not use it. | ||
SONY |
CDP55
|
Door opens by itself | After the first repair in which the belt was replaced, thecustomer complained of the same problem. 1. after opening the tray totake out a disc, the tray will close by itself before another disc can beput into the tray. 2. tray opens by itself. | ||
SONY |
SLHF900
|
Can play pre-recorded tapes but not tapes recorded on itself | Unit would play pre-recorded tapes but not tapes recorded onitself. | ||
SONY |
KV27XBR10
|
Interference pattern across screen, replaced comb filter | Interference pattern across the screen which looked likesignal overload. scope shot looked ok at input, pin 2 cm-1301, but noisepresent at output pin number 6, y out. suspected this part was bad. | ||
SONY |
MDP200
|
No clv lock on cd - no play - ld ok | Unit plays ld but not cd. looked like clv servo problem. | ||
SONY |
D90
|
Runs in test mode, shuts down in normal operation | Unit would achieve focus, sled would move toward center ofdisk and continue reading t.o.c. data then shutdown. looking at rf testpoint, showed signal typical of t.o.c. area: fok, sense, h. in signalsappeared normal. | ||
SONY |
CCDF55
|
Won't thread a tape | Intermittently, drum won't start. | ||
SONY |
CCDF50
|
No camera or playback video out | Unit had no camera, playback or ee video. signal was goodgoing into input select ic-362 pin 28 (va-board). video looked clipped atpin 11 and no signal was present at pin 4. changing ic-362 had no effect.found no serial data i/o at pins 20-23. traced | ||
SONY |
CCDF40
|
No camera or playback video out | Unit had no camera, playback or ee video. signal was goodgoing into input select ic-362 pin 28. (va-40 board) video looked clippedat pin 11, and no signal was present at pin 4. changing ic-362 had noeffect. found no serial data i/o at pins 20-23. tr |