SONY KV32HSR10
No picture, to disable ik sense line for troubleshooting As you may have noticed, when servicing this and other unitsusing this particular ic-301, rgb lines at the ic level are blanked any-time the c board is disconnected. the main reason for this blanking isa cathode current detect line (ik). when the unit
SONY KV27XBR65
No picture, how to trouble shoot the ik circuit As you may have noticed, when servicing this and other unitsusing this particular ic-301, rgb lines at the ic level are blanked any-time the c board is disconnected. the main reason for this blanking isa cathode current detect line (ik). when the unit
SONY KV27XBR60
No picture, troubleshooting the ik line As you may have noticed, when servicing this and other unitsusing this particular ic-301, rgb lines at the ic level are blanked any-time the c board is disconnected. the main reason for this blanking isa cathode current detect line (ik). when the unit
SONY KV27XBR50
Trouble shooting information on the ik line As you may have noticed, when servicing this and other unitsusing this particular ic-301, rgb lines at the ic level are blanked any-time the c board is disconnected. the main reason for this blanking isa cathode current detect line (ik). when the unit
SONY KV27XBR15
No picture, how to troubleshoot As you may have noticed, when servicing this and other unitsusing this particular ic-301, rgb lines at the ic level are blanked any-time the c board is disconnected. the main reason for this blanking isa cathode current detect line (ik). when the unit
SONY KV27XBR10
No picture, how to troubleshoot the ik circuit As you may have noticed, when servicing this and other unitsusing this particular ic-301, rgb lines at the ic level are blanked any-time the c board is disconnected. the main reason for this blanking isa cathode current detect line (ik). when the unit
SONY KV27EXR15
No picture, ik related troubleshooting As you may have noticed, when servicing this and other unitsusing this particular ic-301, rgb lines at the ic level are blanked any-time the c board is disconnected. the main reason for this blanking isa cathode current detect line (ik). when the unit
SONY KV20EXR10
No picture, how to troubleshoot As you may have noticed, when servicing this and other unitsusing this particular ic-301, rgb lines at the ic level are blanked any-time the c board is disconnected. the main reason for this blanking isa cathode current detect line (ik). when the unit
SONY KV27EXR10
No picture, ik line related troubleshooting As you may have noticed, when servicing this and other unitsusing this particular ic-301, rgb lines at the ic level are blanked any-time the c board is disconnected. the main reason for this blanking isa cathode current detect line (ik). when the unit
SONY CDPC20
Alternative method to repair bu bracket support on frame A common failure on the cdpc20/30/40/50/70 series of playersis the need to replace the frame because the support that holds up the bubracket breaks. replacing the frame can take up to one hour. by using thespring from the cdxa10 as the new support for th
SONY KV27EXR15
Clock gains time, see sb tvp087r1 Unit would gain two hours a day. the home tech at costa mesainstalled the modification (tech flash no. 39). home tech informed meit resolved the problem.
SONY PVM2030
Screen not completely blanked With brightness and picture control turned down and in a darkroom, there is a visible illumination on a part of the tube. this is withno connections to video in. connecting a generator to the video in andstarting with minimum signal, you can see the pr
SONY GV9
No audio on playback No audio on playback but unit records audio.
SONY FD240
Pyramid picture/raster on screen, resoldered l-501 Getting a pyramid picture and raster on the screen.
SONY FD230
Pyramid picture/raster on screen Getting a pyramid picture and raster on the screen.
SONY D2
Unit does not function Unit does not function. display works ok. no sled, spindlemotor or fop movement. service mode is same as above.
SONY CDPC900
Will not load disc There is a lot of free play in roller and brass bushing.eventually, the gear that drives the roller comes out or the bushing fallsout or both.
SONY EDV9500
Streaking on peak whites during playback When playing a tape with white highlights or keyed insertlettering, streaking could be observed.
SONY GEN-HFP
Accessibility of 1/2 vcc points Accessibility of 1/2 vcc points on these models:d9, cdxr77, cdxr79, cdx7540, cdx7580. -solution the 1/2 vcc points on these models are as follows:model 1/2 vcc point location dc voltage----- ----------------------
SONY EDV9500
Problem on new video head After replacement head was installed, the rf envolope from onehead was very low. lapping head for 10 seconds restored proper operation. -hq comments: new video heads will sometimes have sharp edges, andwill pick up oxide from the tape surface. lapping