Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
SONY |
WM75
|
No p/n - packing material, headphone jack | No p/n for rubber packing which goes in the headphone jacks. -hq comments: p/n is 3-326-140-01. we will issue a s/b. | ||
SONY |
CFS950
|
No p/n - rubber gasket | No part number for rubber gasket that fits into (cabinet assy,front) ref #28. -hq comments: this item does not come separately. you must order thecabinet. we have asked tokyo to provide it in the future. | ||
SONY |
CDXR7
|
Noise from unit when powered on | When unit is powered on with disc off (tuner on, disc in orout of unit) noise is emitted from optical pick-up. noise is generatedfrom stator board. turning spindle by hand increases/decreases level.moving the disc table up or down on the shaft increase | ||
SONY |
SLHF900
|
Fm modulator deviation adjustment | Rv207 had to be replaced. deviation alignment on page 274requires a spectrum analyzer. | ||
SONY |
SLHFR70
|
Interference | Interference when vcr off and tv on active channel 3 (2 and 4not affected). interference rolls through picture, flashes when clockflashes on vcr display. scope shows interference on pins 14 and 15 of ic1power supply. problem appears only 5-10 min. aft | ||
SONY |
KV2680R
|
Low audio, replace vol buffer q-1126 on x board | The unit had very low audio on all functions. we found theproblem to be caused by a defective volume buffer/q1126. | ||
SONY |
SL20
|
Scanning would not stop on channel | In channel up or down mode, scanning would not stop onchannel. scanning continued to end of range. h sync pulse to systemcontrol ok. | ||
SONY |
WMF75
|
Intermittent auto reverse | Spurious auto reverse. the shut-off lever (b) was sticking. | ||
SONY |
ITA500
|
Operation of transfer mode and out mode | Customer complains of line capture in 1 1/2 rings and calltransfer - if line busy ita-500 waits 1 hr to recall. can this time bechanged? -hq comments: these operating parameters are programed into the micro-processor. they candesire concerning these a | ||
SONY |
KV1396R
|
No audio, replaced r255 | This unit had no audio. the collector resistor for q252 wasopen although it does not show a resistor number in the schematic. it ismarked r255 on the board. | ||
SONY |
KV2697R
|
Problem with factory installed modification, q-102 leaky | Unit would turn on and off with front panel. no other functions would operate. remote hand unit would turn set on but not off. no other functions on remote would work. set came on displaying aux. | ||
SONY |
SLHFR70
|
No tuning | Would not tune, no memory. | ||
SONY |
SL3030
|
Blanking bar ghost and christmas tree effect | This unit had a problem with a blanking bar ghost and christ-mas tree effect in the picture through the tuner on e to e mode only whencable signal was connected. the picture was good on a regular antenna. | ||
SONY |
KV25XBR
|
Button part numbers missing | The part numbers for the aux/ant and the cable on/off switchbuttons are not in the manual. the two above mentioned buttons are notpart of the switches and do not come with the assembly #63p/n 4-374-151-01. i need these two buttons (rush). -hq comments | ||
SONY |
EVC8U
|
Counter does not work | Counter does not work. | ||
SONY |
CCDV8AFU
|
Unit shuts down in ff or rew | Will ff or rew for about 100 on counter, then unit shuts off. | ||
SONY |
XR740
|
No display | Unit had no display, no scan down, no #6 position. | ||
SONY |
CCDV8
|
No color recording | No color in e-e or recording. playback of pre-recorded tapesok. | ||
SONY |
SLHF400
|
No pix only noise in scan | After warm up in the scan mode picture breaks up. playbackfine. | ||
SONY |
KP5020
|
Missing resistors cause overscan | A new g board was installed to replace a cracked one. the newboard caused the unit to be overscanned by about 20%. we found theproblem to be caused by missing resistors. these were r814 and r815 inthe 110v regulator. this caused the b plus to be exce |