SONY KV2647R
No color, replace ic501 No color. very low burst.
SONY KV2645RS
No uhf, replaced prescaler bt-981 No uhf, vhf ok. all voltages and pulses present excepttp-59.
SONY KV1943R
Intermittent sound, replaced c226 Highly intermittent audio. slight popping noise beforegoing out.
SONY KV1923
Tuning up/down would not lock In the program mode tuning up/down set will not lock onchannel.
SONY KV1914
No sound No sound. voltage at pin 21 of ic201 was low, should havebeen 5.8 vdc, was only 4.0 vdc.
SONY KV1543R
Intermittent color fade, replaced c308 Intermittent color fading. this problem was highly inter-mittent, sometimes taking weeks to manifest itself. the color would fadeout completely. chroma input to ic301 pin 13 would not change at allduring fade outs. dc level was varying slightly, betw
SONY KV1515
No vhf channel Low vhf channels cannot be received. found d501, d502shorted.
SONY KV1221R
No remote control function, replaced c007 There were no remote control functions. the volume up/downfunctions would shut set on and off. manual input of ic (remote control)pin 1 always had a noise pulse and frequency at this point was incorrect.this noise pulse inhibited any input data from re
SONY KP7220
No picture, connector da-5 intermittent Connector da-5 gets loose and causes picture tubes to blankout, can also cause a line on green tube which burns to mark in tube.
SONY KP5040
Poor focus, replaced hv block Unable to get a good focus. problem traced to high voltageblock.
SONY KP5040
Dead, replaced cx171, q5521, q5522 Set would not turn on. servicer found cx171 defective whichis believed to have caused q5521 and q5522 to short, fuse found defective.
SONY KV2145R
Set locks on ch 88, replaced ch indicator nd3101 Set was locked onto channel 88, unable to clear or change.found pulse out of ic001 on mf board loaded down. traced problem tochannel indicator display nd3101 on ta board. pin 3 on display isshorting to something inside display loading down pin 40 on ic
SONY KV2141R
No picture, leaky d511 zener Unit completely out of horizontal frequency. at pin 8 ofic501 the dc voltage reads 4v instead of 10v. trouble traced back toleaky d511 (rd15e).
SONY KV1945RS
Picture distortion, replaced ic501, cx-557 About the top 10 scan lines were stretch, very hard to detectbut customer complained. vertical output waveform could see ringing,apparently leakage in the ic from horizontal.
SONY KV1921
Shut down Unit shuts dowm erratically. this problem confused theservicer because the original problem was a shorted damper. when ac wasapplied, the unit ran fine up to about 90v ac in then suddenly guit.by using light bulb technique we located q510 breaking down
SONY KV1913
No sound No sound, momentary raster. found q206 and q205 leaky whichdrags the 135 b+ low (70v).
SONY KV1913
No vhf low No low (2-6) channels. could not get high (7-13) band toturn off. found d101 leaky.
SONY KV1910
Faint retrace lines on specific channel only Faint retrace lines only on channel 7. this problem appearedonly when the set was turned to cable 7. it was observed that thevertical sync pulse was compressed on this channel. this resulted in5-6 retrace lines appearing at top of screen. linearity w
SONY KV1207
Picture noise Vertical bars across screen, excess ringing off 190v line offlyback. c540 was missing from circuit.
SONY KV1207
No low vhf No low vhf channels, voltage on q102 remains high regardlessof band switch position. found d059 diode on m4 board leaky.