Toshiba Repair Tips
Search: toshiba
Results: 5592
Results: 5592
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
TOSHIBA |
TV2998
LEM4 |
Image very dark, even at maximum brightness and contrast | The 100pf x 2kv disc capacitor c-902, even when measured, is perfect up to the value on the capameter | But removing the circuit the brightness returns to normal (screen) | savoy |
TOSHIBA |
TV1483FAV-U11
|
No audio | Speaker | Replace the same | eletronicaapolo |
TOSHIBA |
2083
U11 |
No image, no characters, blue screen and no sound. | 1n4148, in position d901 on the kinescope PCB. | Just replace and run for the hug. | Tec vídeo |
SEMP TOSHIBA |
2091KAV
U15 |
Burning th bu808dhi. | I changed the bu808dhi, it is heating up a lot so I also changed the 47x50v capacitor c 419 ok | C419 sem capacitance | Danil |
SEMP TOSHIBA |
TV 20A82 EAV
U8 |
Totally inoperative | Q.801 (strz 2264)- dz. 877 (uz 9.1 v bsa)- dz.878 (uz 27 v bsc) | What. 801 was broken in total short, I replaced it, before turning on the TV I checked the other components that work in the power supply area, I found the dz. 877 and the dz 878 shorted out, I replaced the other components and the TV was beautiful, ok | edluz |
TOSHIBA |
TV 20A82 E AV
U8 |
Horiz exit. getting very hot | Ceramic capacitor ( c- 463 de 2k2 pf ) q-402 ( 2sc 2482{fa1} | edluz | |
TOSHIBA |
TV2085-FM
U11 |
Flyback high voltage leakage, supply +/-130v | Flyback exchange, obs power supply without load is 130v on and 123 off, with load 115v | GENIVALDO | |
TOSHIBA |
TV2996S
|
Taking a while to start stand by | By the way, I thought it was a capacitor, so I checked and found cap.c819, all the caps I tested were bad!!! | Swap c819 | Toninho Pacheco |
TOSHIBA |
UNIVERSAL 14
|
Reducing vertical at the top | Ic qa21 5v regulator | ITAN PARELHAS | |
TOSHIBA |
2998
LEM |
Does not obey control | Low reset voltage | Capacitor ac 33 shorted | ITAN PARELHAS RIO DE JANEIRO |
TOSHIBA |
2999
LEM 6 |
With blue screen when changing channels | D 621 as escape | ITAN PARELHAS RIO DE JANEIRO | |
TOSHIBA |
3488
LEM 4 |
Darkening the image | C 902 1kx 2kv | On the tube plate, replace without measuring | ITAN PARELHAS RIO JANEIRO |
TOSHIBA |
UNIVERSAL 13
|
Folded vertical | Swap memory | ITAN PARELHAS RIO DE JANEIRO | |
TOSHIBA |
UNIVERSAL 13
|
No flashing color | C 526 2k2 replace | ITAN PARELHAS RIO DE JANEIRO | |
TOSHIBA |
UNIVERSAL 13
|
S contrast | R227 open c 445 change, c 226 short tube could be bad | ITAN PARELHAS RIO DE JANEIRO | |
TOSHIBA |
UNIVERSAL 13
|
Reduced vertical | Replace ci 8803 | ITAN PARELHAS RIO DE JANEIRO | |
TOSHIBA |
UNIVERSAL 11
|
Keyboard does not work and when plugged in it comes on | Swap memory | ITAN PARELHAS RIO DE JANEIRO | |
TOSHIBA |
UNIVERSAL 15
|
Closing the intermittent vertical | Change c301 connected to | ITAN PARELHAS RIO DE JANEIRO | |
TOSHIBA |
UNIVERSAL 14
|
Does not turn on at 220 | Exchange r 840 from 3k7 for one from 2k2 | ITAN RIO DE JANEIRO, PARELHAS | |
TOSHIBA |
LEM 2
|
Noisy image | Noisy image | Replace c 213 | ITAN PARELHAS RIO DE JANEIRO |