Search: daewoo
Results: 145
Make Model Symptom Problem Solution By
DAEWOO CP775
Txt lines on bottom 1/3 pic with sat & vcr Tda8351 fop chip
DAEWOO CP775
Service remote substitute Can use universal from toptel4 or gumbody 4 code = 244 for serv rem r30svc
DAEWOO CP775
Pic slow to come on - sound ok Replace tda8375a jungle chip
DAEWOO CP775
No signals - fault in tuner . replace 4-legged device ( dual gate fet smd transistor marked mos ) inside the tuner near aerial input. i used generic bf998 marked mop
DAEWOO CP775
Nicam cracles Replaced sawf for analogue type to prevent operation - bodge!
DAEWOO CP775
Dead with psu running No or low line drive at base q402 line dr - check trs q405 2sa854 & q406 2sc945 for leak
DAEWOO CP775
Dead - lop tr q401 2sd1880 s/c C416 blue disc cap 680pf 2kv s/c. d503 1n4148 s/c; rc527 10r chip res; r503 10k; r409 4k7 were cause of problem
DAEWOO CP760
Pic displaced to left Crack in pin 10 loptx - no fback pulse to line gen afc loop
DAEWOO CP420 GB14F7T1
Int reverts to st/by Rly2 relay was operating when fault occurred - ic i807 (top210-pf1) the standby switch mode ic in the power supply
DAEWOO CP380
Blank raster, no sound, osg or r/c when first switched on (ok after re-switched on) Earth speakers/grill to crt rimband
DAEWOO CP365
Sound - int crackle Invisible dry joint c808 270pf 1kv - pin 3 pri of chopper tx
DAEWOO CP365
Int signals Dry joints sec of chopper tfmr
DAEWOO CP365
Int loss of signals - osd ok Dry joints chopper tfmr
DAEWOO CP340
Int sw off Top210pfi, i807
DAEWOO CP330/CP365
Txt absent/garbled Xt01 27mhz xtal
DAEWOO CP330/CP365
No pic or line drive Check drive pin 37 i701 tda8362b, if none check 8.2v pin 36, if present replace chip, if absent check r401/2, d401
DAEWOO CP330/CP365
Magenta cast after i501 replacement I501 tda4661 chroma delay line chip could be faulty
DAEWOO CP330
Jumps chans and sound varies 24c08p eprom memory chip iv02 - use daewoo type
DAEWOO CP310
St/by only - relay clicks at sw on Replace ht pot vr801 4k7, d807 byv95c, q801 2sd1555 & i801 chopper chip tda4601 & check for dry joints
DAEWOO CP240 GB20F8T2
To set up & service mode… Put set in standby then press blue yellow green red & standby to get into svc, to adjust use 4 & 7, vert centre 5 & 8 size 6 & 9 slope yellow, blue horiz centre 123 & above to ajust rgb