Daewoo Repair Tips
Search: daewoo
Results: 145
Results: 145
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
DAEWOO |
CMC1418AD
|
Monitor is not on, a fuse f801 is good. | Check r803, r804, r621, ic801. | ||
DAEWOO |
CMC1418AD
|
Monitor is not on, a fuse f801 is open. | Check of c806, d801, ic801. | ||
DAEWOO |
CMC1418AD
|
Not work a regulation of bright. | Check of d113, c123, vr501, vr502. | ||
DAEWOO |
CMC1418AD
|
Fuse blowing. | Check: c806, d801 and ic801. | ||
DAEWOO |
CMC1418AD
|
The size on vertical is not adjust. | Check of ic101, q203-q205, ic201. | ||
DAEWOO |
CMC1418AD
|
Shift on vertical and is not adjust. | Check of c231, vr112, q214, q215. | ||
DAEWOO |
CMC1418AD
|
Size on width not in rate and is not adjust vr103, vr110. | Check of ic202, c212. | ||
DAEWOO |
CMC1418AD
|
Vertical line. | Check of l105, c126. | ||
DAEWOO |
CMC1418AD
|
No high voltage. | Check of q104, d107, d108, c116, c117. | ||
DAEWOO |
CMC1418AD
|
No high voltage. | Q104, d107, d108, c116 e c117. | ||
DAEWOO |
CMC1418AD
|
The pictures is removable on width and is not adjust vr101. | Check of ic103, c181-c183, r184. | ||
DAEWOO |
CMC1418AD
|
Does not turn on - fuse ok. | R803, r804, r621 e ic801. | ||
DAEWOO |
CMC1418AD
|
Power supply voltage deficiency. | C813, c814, r615 e ic801. | ||
DAEWOO |
CMC1418AD
|
No image. | Q805, q806, ic501 e ic801. | ||
DAEWOO |
CMC1418AD
|
One of the colors is missing. | Ic801, q821, q824, q811, q814,q801 e q804. | ||
DAEWOO |
CMC1418AD
|
Does not adjust contrast. | Q401, q402, vr401, vr402, r403,c813 e ic801. | ||
DAEWOO |
CMC1418AD
|
Does not adjust brightness. | D113, c123, vr501,vr502. | ||
DAEWOO |
CMC1418AD
|
Irregular height without adjustment. | Ic101, q203 e q205. | ||
DAEWOO |
CMC1417AE
|
Noncvoltage of exit does not ignite,no illumi | Replace ic001 stk 73410ii . | ||
DAEWOO |
CMC1414ADE
|
Dead low ht | C014(1uf50v) loptr=line output transistor loptx=line output transformer (flyback) hot=running for 20mins or more |