Lg Repair Tips
Search: lg
Results: 4875
Results: 4875
Make | Model | Symptom | Problem | Solution | By |
---|---|---|---|---|---|
LG |
563 STUDIO WORKS
|
It doesn't turn on, it keeps making small clicks at the power supply | Replace q719 and c744 both on the +b line | AdrianChapadão | |
LG |
RP-29C25
|
Before replacing the horizontal output transistor | Remove r 852 – l0Ω and install a jumper; replace c 854 of 100uf x 16v by 1000uf x 16 v | ||
LG |
STUDIOWORKS 500G
|
Vertical slightly closed | R604 slightly changed | ||
LG |
FLATRON L1550S
|
When turning on the image flashes and becomes dark | Check chap. 470uf at power supply, replace with 35v c | ||
LG |
29FA30
|
When adjusting g2 image increases and decreases | Q407 | ||
LG |
29FA35 A
|
Doesn't start | C405 | ||
LG |
29C85
|
LED pulsating, power supply varies | Zener zd808 | ||
LG |
RP-21FB32
|
It takes 10 to 20 seconds to turn on. | Verficar d23 | ||
LG |
RP-21FB32
|
Takes time to call | Lost | ||
LG |
29C85
|
Doesn't work, 12v short | C404 no pino 28 do ic501 | ||
LG |
29CC9RL
|
Image ripples | C837, check c883 | ||
LG |
LM-U1350A
|
IC703 burns (shorts out) | Before replacing the ic check pc901, pc902 and ic949 and the peripherals | ||
LG |
29CC9RL
|
Does not adjust horizontal phase | R412 | ||
LG |
L1530S
|
The image appears and disappears quickly | C. electrolytic 470uf/25v at 12v power supply. | ||
LG |
29FS4RLG
|
Does not demagnetize | Q811, attention in some manuals it is referred to as q809 | ||
LG |
29FX5CL
|
High fountain, your protection | Infants0 | ||
LG |
RP-29CC25
|
No color only on av inputs | Enter service mode (menu on panel +menu on c.r) av multi option, which should be set to "0". change it to "1". | ||
LG |
RP-21FB32
|
You have to insist to turn it on, after turning it on, changing the channel takes a long time | Lost | ||
LG |
DK-140
|
Does not open the drawer from the panel, it only opens with the control | Ci 901 to painel (pt 6965) | ||
LG |
DV-8921N
|
Parar progressive scan | Press the stop button on the control or on the DVD panel for more than 5 seconds and it returns to normal.... |