MITSUBISHI EURO 12
No signals aft 5 mins Dry joints 4mhz xtal in prescaler
MITSUBISHI EURO 12
No audio pback from mono vcr or sat rx Ic702 eeprom (new one needs reprog) or get kit ic702-kit; pt no of chip = 263p434020
MITSUBISHI EURO 12
Luminance int Q202 j501q
MITSUBISHI EURO 12
Lines on pic with whistling C956 2200µ 16v in psu
MITSUBISHI EURO 12
Int sound/pic - comes & goes with a tap Dry joints vif module
MITSUBISHI EURO 12
Int sound/pic - comes & goes with a tap Dry joints if can
MITSUBISHI EURO 12
Int nicam crackling - tuner drift Dry joints if unit esp on sawfs & coils
MITSUBISHI EURO 12
Int field foldover/lack of height - low ht at 87v No set ht control, crack in print between base q952 & r956/7 junction
MITSUBISHI EURO 12
Int blows q552 Dry joints t551
MITSUBISHI EURO 12
Hum in st/by & no degaussing C960 1000µ 35v in 24v supply
MITSUBISHI EURO 12
High ht - should be 120v C906 47µ 50v, c909 2µ2 50v & 2 x 3v zener diodes d907 & 908
MITSUBISHI EURO 12
Freq blows sd1887 sw mode transistor Mod kit avail from wve (q901 modkit) & change tea2261
MITSUBISHI EURO 12
Field collapse Ic451 tda8178s (must use correct one or foldover occurs if tda8178fs is used - very expensive!) also check c452 220µ 35v & 122v ht at tp91
MITSUBISHI EURO 12
Field collapse Replace tda8178s & check c956 1000µ 35v, c452 220µ 25v & ht - mitsi mod kit 2 available from grandata (cheaper)
MITSUBISHI EURO 12
Field collapse Replace chip - must be same suffix - use phoenix repair kit from grandata
MITSUBISHI EURO 12
Field collapse No 28v to tda8178s - r976 0r82 in psu o/c
MITSUBISHI EURO 12
Excess width, bowed verts & pic shifted sideways Low amp h sync fback pulse from lop - d559 1n4148 s/c - check for dry joints loptx
MITSUBISHI EURO 12
Excess width Tea2031a
MITSUBISHI EURO 12
Dies at sw on with squealing C956 1000µ 35v, c958 1000µ 16v, c964 1000µ 50v leaky & dry joints & ic551 (e/w chip) & tea2031a damaged
MITSUBISHI EURO 12
Dead or int reverts to st/by - loptr q522 fails periodically - possibly due to high ht C906 47µ 50v drive coupling cap - also check c905 470µ 35v, c909 100µ 25v,c920 100µ 25v, r961 150k, r972, r960, d907 rd3.0 s/c & ic950; q522 = 2sd1877 (21"), 2sd1878 (25"), 2sd1879 (29")