MITSUBISHI EURO 12
Dead apart from 3 chirps at sw on Loptr 2sd1878 s/c also replaced c956 47µ in psu
MITSUBISHI EURO 12
Dead - off with bang C906 47µ 63v, q901 2sd1887, r901 4r7 10w, ic901 tea2261, d907/8 rd3.0fb1, c920 100µ 63v - c975 47µ 63v was the cause
MITSUBISHI EURO 12
Dead - loptr s/c due to high ht Check r961 150k & c906 47µ 50v & ic950
MITSUBISHI EURO 12
Dead - chopper q901 & lop tr q552 u/s Q901 serv kit fitted & q552 2sd1878 also c905 470µ 35v, c906 47µ 50v, c909 2µ2 50v, c920 100µ 25v
MITSUBISHI EURO 12
Dead - blows q901 C906 47µ 50v
MITSUBISHI EURO 12
Dead Q552 2sd1878 s/c; r901 4r7 10w o/c
MITSUBISHI EURO 12
Contrast low with fb lines Ic251 pin 7 only 1.2v instead of 2.9v; 12v line low as q704 leaky
MITSUBISHI EURO 12
Blue excessive (or green/red) D656 leaky on crt base ( or d655, d657)
MITSUBISHI EURO 12
Black box appears on screen &/or no txt C958 1000µ 16v in 5v supply
MITSUBISHI EURO 11 CT25B3
Int comes on with small pic - other times ok Ht was low at 105v (145v) - check/change caps in psu sec
MITSUBISHI EURO 10 CT21M1TX
Sideways wobble to pic C905 470µ & c906 47µ in psu pri
MITSUBISHI EURO 10
Switches off immediately after powering up Check pc951 opto coupler
MITSUBISHI EURO 10
St/by only after being int for previous 2 days Dry joints loptr q552 2sd1878
MITSUBISHI EURO 10
Sound dist Ic361 an5264 audio o/p chip dry joints
MITSUBISHI EURO 10
Popping noise fro speakers in st/by ; 20v supply not being sw off Q5951 jc501-q faulty or dry jointed, q952 2sa950-y, r954, r974 or r985 can also be responsible
MITSUBISHI EURO 10
Poor contrast Q704 jc501 blanking tr on main pcb
MITSUBISHI EURO 10
Pic fluctuate after few seconds Ht low at 107v (112v) c906 47µ 25v also replaced c905
MITSUBISHI EURO 10
Patterning - clears with a bang on cabinet Ic902 12v reg faulty
MITSUBISHI EURO 10
Not memorising user prefs C962 100µ on -30v supply
MITSUBISHI EURO 10
No sound/pic - no memory & slow r/c response Ic702 eeprom chip st24c02a