Make Model Symptom Problem Solution By
MITSUBISHI EE4 CT21M5BT
Reverts to st/by aft 15mins with a sqeal Ht was too high at 137v, due to r954 (120k in this set) going high
MITSUBISHI EE4 -M5 MODELS
To enter service mode Press & release s701 next to aerial socket, then press "9" on hset within 5 secs. buttons 2 & 8 select adj code, buttons 4 & 6 adj data value. button 1 cancels written data, button 0 stores data into eeprom see article tv jan 99 for more details
MITSUBISHI EE4
Trips once at sw on - ok on dummy load Tea5101b rgb o/p chip ic660 s/c
MITSUBISHI EE4
Service mode accessing Press the service switch (s701, next to the aerial socket) and then button 9 within 5 seconds press the * button to toggle between the vcj or option adjustment display. press buttons 2 or 8 to increase or decrease the adjustment code number. press buttons 6 or 4 to increase or decrease data value. after the adjustments, press 0 to write the adjustment data to the eeprom.to cancel a change, press button 1 and all data adjusted since the last eeprom write will be reset.tun 0 option settings for ct25av1bs = sat 1, aud 10, ats 1, std 1, sys 1, av1 2, eex -, spk 1, eep -, abg 02, a1 02, al 00, adk 15, mnp 70, txt -, fft 1, vol 74, hyp 1, scp 20, fmp 23
MITSUBISHI EE4
Dead or int dead - brief flash of green led at sw on Dry joints opto isol pc951
MITSUBISHI EE3W
Service mode access Press menu, 2, 3, 5, 7 to access service mode, then press * (star key). use 2 & 8 to navigate up and down the options, 4 & 6 to alter values. press 0 (zero) to memorise new value & the info turns red to denote "saved". finally go to standby to exit menu.
MITSUBISHI EE3 CT25AV1BDS
Herringbone pattern, flashing lines etc with no pic for 5 minutes. picture then slowly appears C956 470uf 6.3v
MITSUBISHI EE3
Low contrast, smeary, f back lines R686 on crt base (1k8)
MITSUBISHI EE3
Long time to come on C955 2200µ for 11.5v supply
MITSUBISHI EE3
Lock up & memory problems Replace c955, c702 & r3d68 also change value of r702, r213 & r214 to 1k ¼w
MITSUBISHI EE3
Grey scale varies Crt bias request bit could not be set to 00 with g2 control - not ic201 dec/tbase gen chip.cured by replacing tea5101 rgb o/p chip & diodes d655/6/7 1n4148 on crt base
MITSUBISHI EE3
Green led lit - no other activity Ht secondary supplies ok- no line drive. ic702 eeprom may need reprog
MITSUBISHI EE3
Dead; 2a fuse blown violently & chopper q901 s/c Replace q901 s2000n, ic901 tea2261, opto coupler pc951 tcdt1124g. check d909 zener rd3.0fb2 & r908 0r33 2w & r909 0r22 2w
MITSUBISHI EE3
Dead- initially long time to come on C914 47µ 35v, c955 1000µ 16v
MITSUBISHI EE3
Dead apart from flashing red/green leds C955 1000µ 16v
MITSUBISHI EE3
Dead - q552 s/c due to high ht C914 47µ 35v o/c
MITSUBISHI EE3
Dead - lop tr s2055n leaky then no line dr Q551 fully conducting, q501 jc501-r u/s
MITSUBISHI EE3
Dead Cct prot o/c - uprated to 3.15a from 2a also could be start up res r915 15r 2w, r922, r921 & r902 22k 2w
MITSUBISHI EE3
Dead Avn5-kit is available when q552 has gone s/c - includes r713 1k, r726 5k6, q552 2sd1556, q901 s2000n, r508 3k9 5w, r991 4r7 10w, d909 rd3.0fb2 zener, an additional cap c720 22pf
MITSUBISHI EE3
Crushed whites Q952 8v reg dry joints