Search: philco
Results: 4811
Make Model Symptom Problem Solution By
PHILCO PCM1446 PCM2046
Does not receive RF Check r201 (10k) Sequeira
PHILCO PCM1446 PCM2046
LED lights up but doesn't start Check r908 (82k) Sequeira
PHILCO PCM1446 PCM2046
List almost in the middle of the screen Check r723 and c709 Sequeira
PHILCO PCM1446 PCM2046
No contrast Check r706 and c716 Sequeira
PHILCO PCM1446 PCM2046
Difficulty opening the image, excessive heating of the 9v regulator Check c720 (47/25v) Sequeira
PHILCO PCM1446 PCM2046
Does not oscillate horizontally Check r703 and c706 Sequeira
PHILCO PCM1446 PCM2046
The cutter works Verifier R719 Sequeira
PHILCO PCM1446 PCM2046
Turns off after a while Verifier R706 Sequeira
PHILCO PCM1446 PCM2046
Vertical closed Verifier R601 (680K) Sequeira
PHILCO PCM1446 PCM2046
The vertical shakes, the image twists, it seems out of sync Varificar c205 (2,2/50v) Sequeira
PHILCO PCM1446 PCM2046
Blinking led Check l701 (open or with cold welding) Sequeira
PHILCO PCM1446 PCM2046
Turns on and off after a while Check r716 (100k) Sequeira
PHILCO PCM1446 PCM2046
Turn on and off Check r713 (100k) Sequeira
PHILCO PCM1446 PCM2046
Vertical closed Check diode 302 Sequeira
PHILCO PCM1446 PCM2046
Don't tune in Check c208 Sequeira
PHILCO PCM1446 PCM2046
TV disarming Check diode 302 Sequeira
PHILCO PCM1446 PCM2046
Low power supply with 35v Check str50103 Sequeira
PHILCO PCM1446 PCM2046
Image without red Check zd503 Sequeira
PHILCO PCM1446 PCM2046
Contrast does not work Check c716 Sequeira
PHILCO PCM1446 PCM2046
White screen with scratches and no image Check c719 Sequeira